trait_codetrait_name
CODetectedCarbon Monoxide Detection Status
ExpressedStateAlarm State
WindSettingWind Type
AirflowDirectionAirflow Direction
FanSpeedFan Speed
AirQualityAir Quality Level
BooleanStateBoolean State
FreshAirModeFresh Air Mode
InvertedRotationAngleInverted Rotation Angle
ScreenBrightnessScreen Brightness
TemperatureUIDisplayModeTemperature UI Display Mode
BatReplacementNeededBattery Replacement Needed
BatQuantityBattery Quantity
RechargeableRechargeable
CircuitCurrentCircuit Current
P2PCaptureEnabledP2P Capture Supported
MotorOperationStatusMotor Operation Status
MotorDirectionReversedMotor Direction Reversed
MotorControllabilityMotor Controllability
CurrentValveStateCurrent Valve State
ConditionFilter Remaining Life
ChangeIndicationFilter Life Status
FilterTypeFilter Type
OperationalStateOperational State
CurrentFlowCurrent Flow
CurrentModeCurrent Mode
ChangeToModeResponseMode Change Feedback
VacuumOperationalStateVacuum Operational State
RefrigeratorAlarmRefrigerator Alarm
EvseStateCharging Connector State
EvseSupplyStateCharging Station State
ChargingEnabledUntilCharging Enabled Until
MaxChargeCurrentMaximum Current
BatteryCapacityBattery Capacity
MinChargeCurrentMinimum Current
SetTemperatureSet Temperature
SetTemperatureLevelSet Temperature Level
MediaInputPlayback Source
SetBackTemperature Setback
OpenAngleOpening Angle
BSSIDBSSID
CurrentTemperatureCalibrationTemperature Compensation
HeaterCoolerButtonEventHeater/Cooler Button Event
HeaterCoolerPolarityHeater/Cooler Polarity Setting
SelfCheckAlarm Self-Test
FirmwareRevisionFirmware Version
SerialNumberSerial Number
VendorNameVendor Name
VendorIDVendor ID
ProductNameProduct Name
ReachableConnectivity State
HardwareVersionHardware Version
MacMAC Address
DeviceIDDevice ID
EndpointNameDevice or Card Name
OnOffOn/Off State
CurrentLevelCurrent Level
CurrentXX Value
CurrentYY Value
ColorTemperatureColor Temperature
ButtonEventButton Event
CameraActiveStatusCamera Sleep State
CurrentPositionPercentageCurrent Position Percentage
TargetPositionPercentageTarget Position Percentage
IRTypeInfrared Type
IRBrandInfrared Brand
CurrentVoltageVoltage
CurrentPowerPower
CumulativeEnergyConsumptionCumulative Energy Consumption
HeaterCoolerModeHeating/Cooling Mode
HeatingTemperatureHeating Temperature
CoolingTemperatureCooling Temperature
FanModeFan Mode
RockSettingOscillation
CurrentHumidityHumidity
CurrentPlaybackStatePlayback State
PlaybackDurationDuration
SampledPositionPlayback Progress
PlaybackModePlayback Mode
MediaInformationMedia Information
VolumeVolume
MuteMute
LockStateLock State
DoorStateDoor State
IRKeyInfrared Command
BatPercentRemainingBattery Percentage
SweeperStateSweeper State
VOCDensityVOC Concentration
VOCQualityVOC Level
CurrentPressurePressure
PM2.5DensityPM2.5 Concentration
PM2.5LevelPM2.5 Level
PM1.0DensityPM1.0 Concentration
PM10DensityPM10 Concentration
CO2DensityCO2 Concentration
CO2LevelCO2 Level
CurrentIlluminanceIlluminance
ContactSensorStateContact State
SmokeDensitySmoke Concentration
SmokeDetectedSmoke Detection Status
GasDensityGas Concentration
GasDetectedGas Detection Status
SleepStateSleep State
SleepQualitySleep Quality
OnBedIn-Bed State
SleepStageSleep Stage
LeakStateLeak State
OccupancyPresence State
OccupancySensorTypePresence Sensor Type
MotionDetectedMotion Detection
RotationAngleRotation Angle
RotationDirectionRotation Direction
RotationEventRotation Event
CubeEventCube Event
VibrationEventVibration Sensor Event
SmokeDensitydBSmoke Density (dB)
CurrentRRed Value
CurrentGGreen Value
CurrentBBlue Value
SupportedEndpointDynamicDynamic Mode Supported
EndpointArrayDynamicDynamic Endpoint Array
FeedFeed
AttitudeDetectedAttitude Detection
TargetPlaybackStateTarget Playback State
EnableRemoteControlEnable Remote Control
HardwareVersionStringSpecified Endpoint Hardware Version
FirmwareRevisionStringFirmware Version
ProductIDProduct ID
MinPINCodeLengthMinimum PIN Code Length
MinRFIDCodeLengthMinimum RFID Length
OperatingModeOperating Mode
ActuatorEnabledActuator Enabled
ReverseIdentifyReverse Identification
HueHue
SaturationSaturation
MinHeatCoolDeadBandMinimum Heating/Cooling Dead Band
ChannelWireless Channel
ExtendedPANIDNetwork Extended PAN ID
WindowCoveringMotorsBindingWindow Covering Motors Binding
CurrentRotationAngleCurrent Rotation Angle
TargetRotationAngleTarget Rotation Angle
CurrentGarageDoorStateCurrent Garage Door State
TargetGarageDoorStateTarget Garage Door State
HoldRotationAngleHold Rotation Angle
ModeCountMode Count
PlaybackSampledPositionPlayback Sampled Position
SelectedMediaOutputSourceSelected Media Output Source
LockOperationLock Operation
DoorLockAlarmDoor Lock Alarm
LockUserChangeLock User Change
ModelValueModel Value
EndpointCountEndpoint Count
EndpointStructureEndpoint Structure
EndpointDeviceTypesEndpoint Device Types
EndpointDynamicCountEndpoint Dynamic Count
EndpointArrayEndpoint Array
EndpointFunctionsEndpoint Functions
SelectedEndpointDynamicSelected Endpoint Dynamic
PartNumberPart Number
BLVersionBL Version
ManufacturerChipIDManufacturer Chip ID
SupportedMatterRolesSupported Matter Roles
HubConnectionStatusHub Connection Status
DeviceXCodeDevice X Code
MatterSpecificationVersionMatter Specification Version
MCUVersionMCU Version
ConfigurationFlagConfiguration Flag
RadarVersionRadar Version
ConfigurationVersionConfiguration Version
ChipTemperatureChip Temperature
LocationLocation
EndpointTagEndpoint Tag
EndpointApplianceTypeEndpoint Appliance Type
EndpointRoomEndpoint Room
EndpointVisibilityEndpoint Visibility
EndpointIconEndpoint Icon
EndpointStatisticsEndpoint Statistics
EndpointRoomNameEndpoint Room Name
VoiceLanguageVoice Language
EnergySavingEnableEnergy Saving Enable
CurrentSensitivityLevelCurrent Sensitivity Level
TransmissionPowerSettingTransmission Power Setting
HubArkTechEnableHub Ark Tech Enable
BeepEnableBeep Enable
NightLightModeNight Light Mode
OutputInterlockFlagOutput Interlock Flag
ActivityDetectionModeSettingActivity Detection Mode Setting
TimeZoneTime Zone
NumberOfSensitivityLevelIsSupportedNumber Of Sensitivity Level Is Supported
PollingTimePolling Time
InstallationOrientationConfigurationInstallation Orientation Configuration
DetectionModeSettingDetection Mode Setting
LightingModeSettingLighting Mode Setting
ResetModeReset Mode
MagicPairPayloadMagic Pair Payload
SupportedEcosystemSupported Ecosystem
MatterPayloadMatter Payload
HomeKitPayloadHome Kit Payload
BoundEcosystemBound Ecosystem
BatReplacementDescriptionBat Replacement Description
BatChargeStateBat Charge State
BatReplaceabilityBat Replaceability
PowerModePower Mode
WiredPresentWired Present
StateOfLowBatState Of Low Bat
LoadSafetyManagementLoad Safety Management
VoltageSafetyManagementVoltage Safety Management
CurrentSafetyManagementCurrent Safety Management
OverCurrentResponseSettingOver Current Response Setting
TemperatureSafetyManagementTemperature Safety Management
RebootCountReboot Count
RebootReasonReboot Reason
UpTimeUp Time
NetworkInterfacesNetwork Interfaces
AntiDeletionSettingAnti Deletion Setting
AntiDeletionLevelSettingAnti Deletion Level Setting
ActiveHardwareFaultsActive Hardware Faults
DebugInfoDebug Info
FreeMemoryFree Memory
AntiDeletionNotificationAnti Deletion Notification
RoutingAgingCountThresholdRouting Aging Count Threshold
PreOperationModePre Operation Mode
NWKRetransmissionCountNWK Retransmission Count
ZigbeeTotalMessageInOneHourZigbee Total Message In One Hour
ZigbeeCoordMacZigbee Coord Mac
APSRetransmissionCountAPS Retransmission Count
ZigbeeResentMessageInOneHourZigbee Resent Message In One Hour
PANIDPANID
ZigbeeExtendedPANIDZigbee Extended PANID
ZigbeeGeneralDiagnosticsZigbee General Diagnostics
MessageTransmissionFailureCountThresholdMessage Transmission Failure Count Threshold
EnableNWKACKEnable NWKACK
ZigbeeKeySeqNumberZigbee Key Seq Number
LQILink Quality Indicator
ZigbeeFrameCounterZigbee Frame Counter
CCAModeCCA Mode
ZigbeeNextHopMacZigbee Next Hop Mac
EnableAPSACKEnable APSACK
MACRetransmissionCountMAC Retransmission Count
ZigbeeFailedMessageInOneHourZigbee Failed Message In One Hour
ZigbeeNeighborTableInfoZigbee Neighbor Table Info
CurOperationModeCur Operation Mode
ZigbeeAvgSuccessfulResendCountZigbee Avg Successful Resend Count
ZigbeeCoordNetworkKeyZigbee Coord Network Key
LanAccessAddressLan Access Address
RemoteProxyAccessEnableRemote Proxy Access Enable
InternetAccessAddressInternet Access Address
IdentifyTypeIdentify Type
IdentifyTimeIdentify Time
HomeStationCredentialsHome Station Credentials
WiFiChannelWi Fi Channel
ChildDeviceProvisioningStateChild Device Provisioning State
ZigbeeDiagnosticsZigbee Diagnostics
ZigbeeAuthRandcodeZigbee Auth Randcode
ZigbeeAuthRandcodeResponseZigbee Auth Randcode Response
WiFiDiagnosticsWi Fi Diagnostics
MagicPairKeychainMagic Pair Keychain
SupportedNetworkSupported Network
SlaveAddressSlave Address
ThreadDiagnosticsThread Diagnostics
AuthenticationStatusAuthentication Status
WiFiRSSIWi Fi RSSI
CurrentTemperatureCurrent Temperature
PackageRecognitionReportPackage Recognition Report
FaceIDReportFace ID Report
HoldTimeHold Time
ActivityDetectedActivity Detected
PresenceConfigurationPresence Configuration
PresencePresence
HumanRecognitionReportHuman Recognition Report
TripTimeTrip Time
BindingBinding
SupportedBindingDeviceTypesSupported Binding Device Types
SupportedBindingFunctionsSupported Binding Functions
LocalControlDisabledLocal Control Disabled
OutputSwitchingTypeOutput Switching Type
OutputNodeModeOutput Node Mode
StartUpOnOffStart Up On Off
PresetPreset
PresetTypesPreset Types
ActivePresetHandleActive Preset Handle
NumberOfPresetsNumber Of Presets
AntiFreezeTemperatureAnti Freeze Temperature
TiltAngleDeviationTilt Angle Deviation
StationaryStateStationary State
InitialTiltAngleInitial Tilt Angle
EventReportIntervalEvent Report Interval
ObjectOrientationEnableObject Orientation Enable
StationaryTiltAngleStationary Tilt Angle
PeakTiltAnglePeak Tilt Angle
ObjectMotionDetectionEnableObject Motion Detection Enable
ObjectOrientationStateObject Orientation State
CubeWorkModeSettingCube Work Mode Setting
TopFaceTop Face
TopFaceChangedTop Face Changed
HoldRotationIntervalHold Rotation Interval
RotationIntervalRotation Interval
BinaryOutputPVBinary Output Present Value
AnalogInputPVAnalog Input Present Value
LoginStateLogin State
SelectedSourceSelected Source
FlameDetectedFlame Detected
OperationalErrorOperational Error
BridgeDeviceIDBridge Device ID
MultiStateInputPVMulti State Input Present Value
PulseDurationPulse Duration
LoadTypeLoad Type
ThemeIDTheme ID
MaxPageNumMax Page Num
ScreenWidthScreen Width
DataVersionData Version
ThemeVersionTheme Version
ScreenHeightScreen Height
EnableIndicatorEnable Indicator
HeartRateHeart Rate
MultiStateOutputPVMulti State Output Present Value
WaterFreezeDetectorWaterFreezeDetector
StepValueStep Value
LockOperationErrorLock Operation Error
SupportedRemoteFeaturesSupported Remote Features
NumberOfCredentialsSupportedPerUserNumber Of Credentials Supported Per User
NumberOfTotalUsersSupportedNumber Of Total Users Supported
NumberOfYearDaySchedulesSupportedPerUserNumber Of Year Day Schedules Supported Per User
NumberOfPINUsersSupportedNumber Of PIN Users Supported
RemoteControlWithAuthCodeRemote Control With Auth Code
RemoteUnlockRemote Unlock
NumberOfRFIDUsersSupportedNumber Of RFID Users Supported
NumberOfWeekDaySchedulesSupportedPerUserNumber Of Week Day Schedules Supported Per User
VacuumOperationalErrorVacuum Operational Error
DefaultOpenDurationDefault Open Duration
RemainingDurationRemaining Duration
SamplingIntervalSampling Interval
CameraRTSPURLCamera RTSPURL
P2PCaptureStatusP2 P Capture Status
CameraRTSPEnableCamera RTSP Enable
GestureRecognitionReportGesture Recognition Report
BreathingMonitoringBreathingMonitoring
BreathingRateBreathing Rate
CharStringValuePVChar String Value Present Value
VehicleIDVehicle ID
EvseFaultStateEvse Fault State
BuiltInEffectsBuilt In Effects
MaxUserDefinedEffectsMax User Defined Effects
CurrentEffectIDCurrent Effect ID
EffectInfoEffect Info
MaxEffectNameLengthMax Effect Name Length
UserDefinedEffectsUser Defined Effects
OnTransitionTimeOn Transition Time
OffTransitionTimeOff Transition Time
ColorModeColor Mode
WhitePointXYWhite Point XY
LEDICQuantityLEDIC Quantity
ColorRGBColor RGB
ColorXYColor XY
StartUpXYColorStart Up XY Color
LightingMusicSyncModeLighting Music Sync Mode
StartUpColorTemperatureStart Up Color Temperature
LightingDynamicSceneModeLighting Dynamic Scene Mode
LightingMusicSyncEnableLighting Music Sync Enable
ColorPointRGBXYColor Point RGBXY
LEDICProtocolLEDIC Protocol
LEDTypeLED Type
MotorSpeedPercentageMotor Speed Percentage
WindowCoveringCategoryWindow Covering Category
UnconfiguredTravelControlPermissionUnconfigured Travel Control Permission
LimitPointSettingLimit Point Setting
ObstacleLimitMarkingBlockTimeObstacle Limit Marking Block Time
MotorSpeedSettingMotor Speed Setting
ManualPullStartStopEnabledManual Pull Start Stop Enabled
ObstacleLimitSensitivityObstacle Limit Sensitivity
TravelConfiguredTravel Configured
WindowCoveringTypeWindow Covering Type
ObstacleLimitAutoReboundEnableObstacle Limit Auto Rebound Enable
ManualPullEventManual Pull Event
WindowCoveringOpenOrientationWindow Covering Open Orientation
ManualPullStartEnabledManual Pull Start Enabled
LimitPointCountLimit Point Count
TargetPositionRotationPercentageTargetPositionRotationPercenta
CurrentPositionRotationPercentageCurrentPositionRotationPercent
ManualPullStopEnabledManual Pull Stop Enabled
ObstacleLimitMarkingEnableObstacle Limit Marking Enable
ManualPullAdaptiveSpeedEnabledManual Pull Adaptive Speed Enabled
DurationOccupiedWithinOneWeekDuration Occupied Within One Week
DurationOccupiedWithinOneDayDuration Occupied Within One Day
FireProductIdentificationFire Product Identification
SmokeChamberContaminationSmoke Chamber Contamination
AlarmErrorAlarm Error
SmokeStateSmoke State
AlarmsEnabledAlarms Enabled
ContaminationStateContamination State
EnableHeartbeatIndicatorEnable Heartbeat Indicator
AnalogOutputPVAnalog Output Present Value
PetRecognitionReportPet Recognition Report
AnomalySoundDetectedAnomaly Sound Detected
RingtonePlayVolumeRingtone Play Volume
RingtonePlayIndexRingtone Play Index
RingtonePlayStatusRingtone Play Status
RingtonePlayDurationRingtone Play Duration
BridgedNodeListBridged Node List
SupportedHubCapabilitySupported Hub Capability
MatterBridgeSupportedMatter Bridge Supported
MatterDACStateMatter DAC State
MatterOnboardingPayloadMatter Onboarding Payload
MatterManufacturerListMatter Manufacturer List
MatterBindStateMatter Bind State
MatterPairingStateMatter Pairing State
MatterPairingSwitchMatter Pairing Switch
BinaryInputPVBinary Input Present Value
VehicleDetectedVehicle Detected

SupportedEndpointDynamic​

Indicates whether the current Device instance supports dynamic configuration.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✘✔

EndpointCount​

Indicates the number of Endpoints contained in the current Device.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueint32✔✘✔
Maxint3265279.0✔✘✘
Minint322.0✔✘✘
Stepuint321.0✔✘✘

EndpointStructure​

Describes the hierarchy (nesting relationships) of Endpoints in the configuration instance used by the current Device.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueEndpointStructureTraitPresentValueStructure✔✘✔

EndpointDeviceTypes​

Describes the Device Type of each Endpoint in all configuration instances of the current Device. Use with EndpointArray or EndpointArrayDynamic.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuelist✔✘✔

EndpointDynamicCount​

Indicates the number of dynamic Endpoint configuration instances supported by the current Device. The default value is 1.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueint32✔✘✔
Maxint3265279.0✔✘✘
Minint320.0✔✘✘
Stepuint321.0✔✘✘

EndpointArrayDynamic​

Describes the Endpoint combination used by the current Device instance. It is mutually exclusive with EndpointArray (only one can be active at a time).

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuelist✔✘✔

EndpointArray​

Describes all possible combinations of Endpoints contained in the current Device. Use with SupportedEndpointDynamic, EndpointDynamicCount, and SelectedEndpointDynamic.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuelist✔✘✔

EndpointFunctions​

This Trait provides access to and reporting for Endpoint function data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuelist✔✘✔

SelectedEndpointDynamic​

Represents the array index in EndpointArray and indicates the currently selected Device Endpoint configuration instance.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueint32✔✔✔
Maxint3265279.0✔✘✘
Minint320.0✔✘✘
Stepuint321.0✔✘✘

ProductName​

Specifies a human-readable (displayable) name for the Endpoint model, such as a manufacturer-assigned model name or other identifier.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

PartNumber​

This Trait provides access to and reporting for part-number data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

BLVersion​

Specifies the Bootloader version. The maximum length is 64 UTF-8 characters.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

ManufacturerChipID​

Identifies the manufacturer chip ID.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint16✔✘✔
Maxuint1665535.0✔✘✘
Minuint160.0✔✘✘
Stepuint321.0✔✘✘

SupportedMatterRoles​

Indicates the Matter roles supported by the device, such as Thread Border Router, Matter Controller, Matter Commissioner, and Matter Bridge. Each bit represents one role.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint8✔✘✔
Maxuint8255.0✔✘✘
Minuint80.0✔✘✘
Stepuint321.0✔✘✘

HardwareVersionString​

Specifies the version number of the Endpoint hardware. The meaning of its value and the versioning rules are defined by the manufacturer. This attribute provides a more user-friendly value than HardwareVersion.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

HubConnectionStatus​

Indicates the connection status between the device and the central Hub, allowing determination of whether the device is currently connected to the central Hub.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueHubConnectionStatusEnum80✔✘✔
Supported Valueslist[HubConnectionStatusEnum8]✔✘✘
Default Valueuint80✔✔✘

DeviceXCode​

Represents the device type X code of the device.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint16✔✘✔
Maxuint1665535.0✔✘✘
Minuint160.0✔✘✘
Stepuint321.0✔✘✘

MatterSpecificationVersion​

This Trait provides access to and reporting for the Matter specification version.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

VendorName​

This Trait provides access to and reporting for vendor-name data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

FirmwareRevisionString​

This Trait provides access to and reporting for firmware-version data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

DeviceID​

Represents the unique identifier of the device.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

VendorID​

This Trait provides access to and reporting for vendor-ID data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

MCUVersion​

Specifies the MCU version. (Present Value: String(64), default: null.)

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

ProductID​

Specifies the manufacturer-assigned numeric ID that uniquely identifies this specific Endpoint product.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint16✔✘✔
Maxuint1665535.0✔✘✘
Minuint160.0✔✘✘
Stepuint321.0✔✘✘

ConfigurationFlag​

Indicates the configuration status. When the flag is set to 1, the device must be configured before it can be used normally.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✘✔

ModelValue​

AIOT model value, for example, lumi.gateway.cn01.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

HardwareVersion​

Specifies the version number of the Endpoint hardware. The meaning of its value and the versioning rules are defined by the manufacturer.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

Mac​

Specifies the MAC address of the device.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

RadarVersion​

Specifies the radar module version. (Present Value: String(64), default: null.)

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

SerialNumber​

This Trait provides access to and reporting for serial-number data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

ConfigurationVersion​

Stores the device ConfigurationVersion and data-model MD5. Each time the app directly connects to the device and builds a new data model, this Trait is compared with the cloud data model to determine whether to update the data model or report a new Trait value.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueConfigurationVersionTraitPresentValueStructure✔✔✔

Reachable​

Indicates whether the device is reachable. 0: Offline; 1: Online.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✘✔

FirmwareRevision​

Contains the current version number of the software running on this Endpoint.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

ChipTemperature​

Indicates the current temperature measured by the device.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✘✔
Maxfloat1000.0✔✘✘
Minfloat-50.0✔✘✘
Stepuint320.01✔✘✘
Default Valuefloat0✔✔✘

Location​

This Trait provides access to and reporting for region data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

EndpointTag​

The Present Value of this attribute must be the ID of a semantic tag within the namespace. 0 represents the aggregate capability, and N (N > 0) specifies the capability of channel N.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint16✔✘✔
Maxuint1665535.0✔✘✘
Minuint160.0✔✘✘
Stepuint321.0✔✘✘

EndpointName​

Describes the Endpoint name as a string with a maximum length of 32.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✔✔

EndpointApplianceType​

Describes the current appliance type, such as Light, Fan, or Air Conditioner. The available type list varies by Device Type.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✔✔
Supported Valueslist[characterString]✔✘✘

EndpointRoom​

Describes the ID of the room where the Endpoint is located, as a string with a maximum length of 32 bytes.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✔✔

EndpointVisibility​

Describes the visibility of all Endpoints contained in the current Device. 0: Invisible; 1: Visible.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✘✔

EndpointIcon​

Describes the current icon ID. The available icon list varies by Device Type and cannot be customized by manufacturers.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✔✔

EndpointStatistics​

Describes whether the device can be included in statistics.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✔✔

EndpointRoomName​

Describes the name of the room where the Endpoint is located, as a string with a maximum length of 128 bytes.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✔✔

VoiceLanguage​

The language used for voice prompts and voice feedback.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueVoiceLanguageEnum81✔✔✔
Supported Valueslist[VoiceLanguageEnum8]✔✘✘
Default Valueuint81✔✔✘

EnergySavingEnable​

Enables or disables energy-saving mode. When enabled, seat temperature, water temperature, and similar settings are maintained at their lowest levels to reduce power consumption.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✔✔

CurrentSensitivityLevel​

Indicates the currently selected general-configuration sensitivity level.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint8✔✔✔
Maxuint8255.0✔✘✘
Minuint80.0✔✘✘
Stepuint321.0✔✘✘

TransmissionPowerSetting​

A dedicated Trait for setting the device transmit power.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✔✔
Maxfloat10.0✔✘✘
Minfloat-32.0✔✘✘
Stepuint321.0✔✘✘

HubArkTechEnable​

Enables or disables the local disaster-recovery capability of proxy Hubs under Aqara Ark Technology. When enabled, if a Hub fails or loses power and some Zigbee devices under that Hub can act as proxy Hubs, the proxy Hub performs certain basic local automations, scenes, and device groups.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean1✔✔✔
Default Valueboolean1✔✔✘

BeepEnable​

Enables or disables audible feedback for device operations.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✔✔

NightLightMode​

Sets night-light mode. In Auto mode, the device automatically turns the night light on or off based on ambient light.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueNightLightModeEnum8✔✔✔
Supported Valueslist[NightLightModeEnum8]✔✘✘

OutputInterlockFlag​

When two attributes have the same value, the states corresponding to those attributes are interlocked.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint80✔✔✔
Maxuint8255.0✔✘✘
Minuint80.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint80✔✔✘

ActivityDetectionModeSetting​

Specifies the device’s current operating mode for detecting and identifying specific activities or states, such as human presence, falls, sleep, or gestures.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueActivityDetectionModeSettingEnum321✔✔✔
Supported Valueslist[ActivityDetectionModeSettingEnum32]✔✘✘
Default Valueuint321✔✔✘

TimeZone​

This attribute sets and reports the device time zone (for example, China Standard Time is "GMT+8"). Correct time-zone configuration ensures that the device system time, scheduled tasks (such as timers), and log timestamps match the user’s actual local time, which is fundamental to accurate operation of all time-related features.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✔✔

NumberOfSensitivityLevelIsSupported​

This Trait provides access to and reporting for the number of supported sensitivity levels.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint8✔✔✔
Maxuint8255.0✔✘✘
Minuint80.0✔✘✘
Stepuint321.0✔✘✘

PollingTime​

Sets the polling interval for communication between the device and the network.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint320✔✔✔
Maxuint32250000.0✔✘✘
Minuint320.0✔✘✘
Stepuint32250.0✔✘✘
Default Valueuint320✔✔✘

InstallationOrientationConfiguration​

This Trait provides access to and reporting for installation-orientation configuration data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueInstallationOrientationConfigurationEnum160✔✔✔
Supported Valueslist[InstallationOrientationConfigurationEnum16]✔✘✘
Default Valueuint160✔✔✘

DetectionModeSetting​

Indicates the current detection-mode setting, which determines the event or state types the device monitors and reports. This configurable parameter can be switched between detection scenarios.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueDetectionModeSettingEnum160✔✔✔
Supported Valueslist[DetectionModeSettingEnum16]✔✘✘
Default Valueuint160✔✔✘

LightingModeSetting​

Defines the operating mode of the lighting device.

The LightingModeSetting Trait sets or queries the current operating mode of a lighting device. This mode determines the range of control capabilities available to the device, including on/off control, brightness adjustment, color-temperature adjustment, and color setting. Four modes are currently supported: monochrome (Level), color-temperature (ColorTemp), RGB, and RGBW. The data points and operations exposed by the device vary by mode.

Specifically, in monochrome mode, a light supports only on/off and brightness control; it does not support color-temperature control or color settings, so this mode is suitable for single-color-temperature dimmable lights. In color-temperature mode, the device also supports color-temperature adjustment, enabling smooth transitions from warm white to cool white, but it still does not support RGB or RGBW color settings; this mode is suitable for tunable-white lights. In RGB mode, the device supports full-color RGB settings in addition to on/off, brightness, and color-temperature control (color temperature can be simulated by mixing RGB channels), but does not support an independent white channel. In RGBW mode, an independent white channel is added to RGB mode. It supports four-channel RGBW color settings that can simultaneously provide vivid colors and pure white light for richer lighting scenarios.

Importantly, the operating mode is not an arbitrary software-level setting; it must usually be determined by the light’s physical wiring and actual deployment. For example, a light connected only to warm- and cool-white LEDs must not be set to RGB or RGBW mode, whereas a light with independent RGB+W pins can use RGBW mode. When the mode changes, the device data-model configuration is dynamically updated: data points unsupported in the new mode are automatically hidden, while supported data points are displayed as needed. This ensures that clients correctly identify the device’s current capabilities and avoid issuing invalid commands. Before changing this mode, confirm that the hardware supports the target mode. Make changes cautiously to avoid abnormal device control or a mismatch between the client UI and the actual capabilities.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueLightingModeSettingEnum80✔✔✔
Supported Valueslist[LightingModeSettingEnum8]✔✘✘
Default Valueuint80✔✔✘

ResetMode​

Supports operations including factory reset and network-configuration reset.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueResetModeEnum8✔✔✔
Supported Valueslist[ResetModeEnum8]✔✘✘

MagicPairPayload​

Provides the pairing information required to commission MagicPair. The value is a structure containing QRCode (the raw pairing QR-code string) and DigitalPairingCode (an 8-digit numeric pairing code). When the device is not bound, reading this payload may activate the MagicPair commissioning window for a period of time (10 minutes by default).

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueMagicPairPayloadTraitPresentValueStructure✔✘✔

SupportedEcosystem​

Indicates the ecosystems supported by the device (for example, Aqara Hub M3 supports Aqara Home, Apple HomeKit, and Matter). The value is a bitmask: bit 0 = Aqara Home, bit 1 = Apple HomeKit, bit 2 = Matter, bit 3 = Aqara Studio, and bits 4–7 are reserved.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint8✔✘✘
Maxuint8255.0✔✘✘
Minuint80.0✔✘✘
Stepuint321.0✔✘✘

MatterPayload​

Provides the pairing information required to commission Matter. The value is a structure containing QRCode (the raw pairing QR-code string) and DigitalPairingCode (an 11- or 21-digit numeric pairing code). When the device is not bound, reading this payload may activate the Matter commissioning window for a period of time (10 minutes by default).

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueMatterPayloadTraitPresentValueStructure✔✘✔

HomeKitPayload​

Provides the pairing information required to commission HomeKit. The value is a structure containing QRCode (the raw pairing QR-code string) and DigitalPairingCode (an 8-digit numeric pairing code). When the device is not bound, reading this payload may activate the HomeKit commissioning window for a period of time (10 minutes by default).

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueHomeKitPayloadTraitPresentValueStructure✔✘✔

BoundEcosystem​

Indicates the ecosystems to which the device is bound. The value is a bitmask: bit 0 = Aqara Home, bit 1 = Apple HomeKit, bit 2 = Matter, bit 3 = Aqara Studio, and bits 4–7 are reserved (and must be 0). For example, 0x03 indicates that the device is bound to both Aqara Home and HomeKit.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint8✔✘✘
Maxuint8255.0✔✘✘
Minuint80.0✔✘✘
Stepuint321.0✔✘✘

CurrentVoltage​

Indicates the currently measured supply voltage. Unit: volts (V).

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✘✔
Maxfloat500.0✔✘✘
Minfloat0.0✔✘✘
Stepuint320.01✔✘✘

CircuitCurrent​

The current flowing through a specific circuit or part of a circuit, typically used to measure current load.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✘✔
Maxfloat10000.0✔✘✘
Minfloat0.0✔✘✘
Stepuint320.001✔✘✘
Default Valuefloat0✔✔✘

CumulativeEnergyConsumption​

This Trait provides access to and reporting for cumulative energy-consumption data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✘✔
Maxfloat1.0E8✔✘✘
Minfloat0.0✔✘✘
Stepuint320.1✔✘✘

CurrentPower​

Indicates the current real-time power consumption. Unit: watts (W).

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✘✔
Maxfloat5000.0✔✘✘
Minfloat0.0✔✘✘
Stepuint320.1✔✘✘

BatReplacementDescription​

This Trait must provide a user-facing battery description.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuestring32✔✘✔
Supported Valueslist[characterString]✔✘✘

BatChargeState​

Indicates the battery charging state. 0: Unknown; 1: Charging; 2: Full charge; 3: Not charging; 4: Not chargeable.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueBatChargeStateEnum8✔✘✔
Supported Valueslist[BatChargeStateEnum8]✔✘✘

BatReplaceability​

This Trait must indicate whether the battery is replaceable.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueBatReplaceabilityEnum8✔✘✔
Supported Valueslist[BatReplaceabilityEnum8]✔✘✘

PowerMode​

Indicates the device power-supply mode. 0: Unknown; 1: Mains power; 2: Battery; 3: DC power.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuePowerModeEnum8✔✘✔
Supported Valueslist[PowerModeEnum8]✔✘✘

BatPercentRemaining​

Indicates the percentage of battery capacity remaining.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat50✔✘✔
Maxfloat100.0✔✘✘
Minfloat0.0✔✘✘
Stepuint320.1✔✘✘
Default Valuefloat50✔✔✘

WiredPresent​

Indicates whether wired power (a power adapter) is detected.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✔✔

Rechargeable​

This Trait must indicate whether the battery is rechargeable.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✘✔

StateOfLowBat​

Indicates whether the battery is in a low-battery state. 0: Normal; 1: Low battery; 2: Critically low.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueStateOfLowBatEnum8✔✘✔
Supported Valueslist[StateOfLowBatEnum8]✔✘✘

BatReplacementNeeded​

This Trait must indicate whether the battery needs to be replaced.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean0✔✘✔
Default Valueboolean0✔✔✘

BatQuantity​

This Trait must indicate the number of individual battery cells or battery packs in a battery source that can be serviced by the user or factory.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint8✔✘✔
Maxuint8255.0✔✘✘
Minuint80.0✔✘✘
Stepuint321.0✔✘✘

LoadSafetyManagement​

A safety mechanism that monitors electrical or mechanical loads.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueLoadSafetyManagementEnum80✔✘✔
Supported Valueslist[LoadSafetyManagementEnum8]✔✘✘
Default Valueuint80✔✔✘

VoltageSafetyManagement​

A safety mechanism that monitors supply voltage and provides protection during overvoltage or undervoltage conditions.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueVoltageSafetyManagementEnum80✔✘✔
Supported Valueslist[VoltageSafetyManagementEnum8]✔✘✘
Default Valueuint80✔✔✘

CurrentSafetyManagement​

A safety mechanism that monitors device current and triggers protection during overcurrent conditions.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueCurrentSafetyManagementEnum80✔✘✔
Supported Valueslist[CurrentSafetyManagementEnum8]✔✘✘
Default Valueuint80✔✔✘

OverCurrentResponseSetting​

This setting defines the scope of overcurrent protection.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueOverCurrentResponseSettingEnum8✔✔✔
Supported Valueslist[OverCurrentResponseSettingEnum8]✔✘✘

TemperatureSafetyManagement​

A safety mechanism that monitors device temperature and triggers protective measures when an overtemperature condition occurs.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueTemperatureSafetyManagementEnum80✔✘✔
Supported Valueslist[TemperatureSafetyManagementEnum8]✔✘✘
Default Valueuint80✔✔✘

RebootCount​

The Present Value must indicate, as accurately as possible, the number of times the device has rebooted. It must increment each time the device reboots, but not when the device wakes from a low-power or sleep state. It must reset to 0 only when the device is factory reset.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint32✔✘✔
Maxuint1665535.0✔✘✘
Minuint160.0✔✘✘
Stepuint321.0✔✘✘

RebootReason​

The Present Value indicates the reason for the device's most recent startup.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueRebootReasonEnum8✔✘✔
Supported Valueslist[RebootReasonEnum8]✔✘✘

UpTime​

The UpTime trait should indicate, as accurately as possible, the time elapsed in seconds since the node was last restarted.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint320✔✘✔
Maxuint324.2949673E9✔✘✘
Minuint320.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint320✔✔✘

NetworkInterfaces​

This trait describes the network interfaces supported by the device.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuelist[NetworkInterfacesTraitPresentValueStructure]✔✘✔

AntiDeletionSetting​

Used to configure protection against accidental deletion.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueAntiDeletionSettingEnum80✔✔✔
Supported Valueslist[AntiDeletionSettingEnum8]✔✘✘
Default Valueuint80✔✔✘

AntiDeletionLevelSetting​

The anti-deletion level setting controls permission for reset-network and factory-reset button operations while the device is running, preventing accidental data loss.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueAntiDeletionLevelSettingEnum80✔✔✔
Supported Valueslist[AntiDeletionLevelSettingEnum8]✔✘✘
Default Valueuint80✔✔✘

ActiveHardwareFaults​

Hardware faults.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueActiveHardwareFaultsEnum32255✔✘✔
Supported Valueslist[ActiveHardwareFaultsEnum32]✔✘✘
Default Valueuint32255✔✔✘

DebugInfo​

Debug information generated while the device is running. The data type is a string with a maximum length of 1024 bytes.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✘✘✔

FreeMemory​

Indicates the device's currently available memory, in kilobytes (KB).

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint32✔✘✔
Maxuint324.2949673E9✔✘✘
Minuint320.0✔✘✘
Stepuint321.0✔✘✘

AntiDeletionNotification​

After AntiDeletion is enabled for a child device on a hub, a notification report is triggered if the child device performs a reset or deletion operation.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueAntiDeletionNotificationEnum8✘✘✔
Supported Valueslist[AntiDeletionNotificationEnum8]✔✘✘

RoutingAgingCountThreshold​

Configures the aging-count threshold for device packet routing.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint85✔✔✔
Maxuint820.0✔✘✘
Minuint83.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint85✔✔✘

PreOperationMode​

Indicates the device's previous Zigbee network connection state.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuePreOperationModeEnum8✔✘✔
Supported Valueslist[PreOperationModeEnum8]✔✘✘

NWKRetransmissionCount​

Indicates the number of network-layer retransmissions during packet transmission.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint83✔✔✔
Maxuint820.0✔✘✘
Minuint83.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint83✔✔✘

ZigbeeTotalMessageInOneHour​

Indicates the total number of Zigbee messages sent in one hour.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint32✔✘✔
Maxuint324.2949673E9✔✘✘
Minuint320.0✔✘✘
Stepuint321.0✔✘✘

ZigbeeCoordMac​

Represents the MAC address of the Zigbee coordinator.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

APSRetransmissionCount​

The number of automatic retransmissions attempted by the Zigbee APS layer when a packet acknowledgement is not received.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint83✔✔✔
Maxuint820.0✔✘✘
Minuint83.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint83✔✔✘

ZigbeeResentMessageInOneHour​

Indicates the number of Zigbee messages retransmitted in one hour.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint32✔✘✔
Maxuint324.2949673E9✔✘✘
Minuint320.0✔✘✘
Stepuint321.0✔✘✘

PANID​

The Present Value indicates the Zigbee network PAN ID.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint16✔✘✔
Maxuint1665534.0✔✘✘
Minuint160.0✔✘✘
Stepuint321.0✔✘✘

ZigbeeExtendedPANID​

A string representing the 64-bit extended identifier of the Zigbee network. Together with the 16-bit PAN ID, it uniquely identifies the network and is typically represented as a 16-character hexadecimal string (for example, “00124B0001234567”).

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

ZigbeeGeneralDiagnostics​

A general reporting channel for child-device self-diagnostic information.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

MessageTransmissionFailureCountThreshold​

Configures the threshold count for failed device packet transmissions.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint810✔✔✔
Maxuint820.0✔✘✘
Minuint83.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint810✔✔✘

EnableNWKACK​

Toggles the option to enable network-layer acknowledgements during network communication.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean0✔✔✔
Default Valueboolean0✔✔✘

RebootReason​

The Present Value indicates the reason for the device's most recent startup.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueRebootReasonEnum8✔✘✔
Supported Valueslist[RebootReasonEnum8]✔✘✘

ZigbeeKeySeqNumber​

Represents the sequence number of the network key currently used by the Zigbee coordinator and identifies the key version. During Magic Pair network joining, the gateway reports this attribute to the cloud or app. The joining device must obtain and configure this sequence number locally to ensure secure communication using the same network key as the coordinator. The default value is 0.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint80✔✘✔
Maxuint8255.0✔✘✘
Minuint80.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint80✔✔✘

LQI​

Indicates the Thread network Link Quality Indicator (LQI), which reflects RF link quality between Thread devices. Range: 0–255.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint8✔✘✔
Maxuint8255.0✔✘✘
Minuint80.0✔✘✘
Stepuint321.0✔✘✘

ZigbeeFrameCounter​

The Zigbee frame counter is a unique incrementing value attached to each data frame to prevent replay attacks and ensure communication security.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint32✔✘✔
Maxuint324.2949673E9✔✘✘
Minuint320.0✔✘✘
Stepuint321.0✔✘✘

Channel​

The Present Value indicates the Zigbee network channel number.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint16✔✘✔
Maxuint1665535.0✔✘✘
Minuint160.0✔✘✘
Stepuint321.0✔✘✘

CCAMode​

Indicates the device's CCA state.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueCCAModeEnum8✔✘✔
Supported Valueslist[CCAModeEnum8]✔✘✘

ZigbeeNextHopMac​

Defines the Zigbee MAC address of the next-hop device.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

EnableAPSACK​

Toggles the option to enable APS acknowledgements during network communication.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean0✔✔✔
Default Valueboolean0✔✔✘

MACRetransmissionCount​

Indicates the number of MAC-layer retransmissions during packet transmission.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint83✔✔✔
Maxuint814.0✔✘✘
Minuint83.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint83✔✔✘

ZigbeeFailedMessageInOneHour​

Indicates the number of Zigbee messages that failed to send in one hour.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint32✔✘✔
Maxuint324.2949673E9✔✘✘
Minuint320.0✔✘✘
Stepuint321.0✔✘✘

ZigbeeNeighborTableInfo​

Provides network-topology information for Zigbee devices.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

CurOperationMode​

Indicates the device's current Zigbee network connection state.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueCurOperationModeEnum8✔✘✔
Supported Valueslist[CurOperationModeEnum8]✔✘✘

ZigbeeAvgSuccessfulResendCount​

Indicates the average number of successful Zigbee message retransmissions.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint32✔✘✔
Maxuint324.2949673E9✔✘✘
Minuint320.0✔✘✘
Stepuint321.0✔✘✘

ZigbeeCoordNetworkKey​

Represents the network key of the Zigbee coordinator.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

LanAccessAddress​

The IP address assigned to the device by the router on the home local-area network (LAN), usually through DHCP. Other devices on the same network, such as a mobile app or computer, use this address to discover and communicate with it locally with low latency.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

RemoteProxyAccessEnable​

Remote proxy access enable switch. This attribute enables or disables the device's ability to be accessed remotely through an Internet cloud proxy. When enabled, authorized users can remotely control the device through a secure cloud tunnel; when disabled, the device can be accessed only on the local-area network (LAN).

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean0✔✔✔
Default Valueboolean0✔✔✘

InternetAccessAddress​

The public access address assigned to the device by the cloud service platform, typically a domain name or NAT-mapped address. Remote management services use this address to locate and connect to the device; it reflects the device's logical location on the wide-area network (WAN).

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

IdentifyType​

Specifies how identification is presented to the user. Values: 0 = none, 1 = light, 2 = LED indicator, 3 = audible indication, 4 = display (visible on screen), 5 = actuator (such as curtain or relay operation), 6–255 = reserved.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueIdentifyTypeEnum8✔✔✔
Supported Valueslist[IdentifyTypeEnum8]✔✘✘

ReverseIdentify​

When triggered through a local action on the device, such as a button press or touchscreen interaction, the device signals all connected client tools, such as a mobile app, web app, or desktop application, so they can locate and identify the corresponding device. Users can quickly find the device in the tool by interacting with it physically.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint8✘✘✔
Maxuint8255.0✔✘✘
Minuint80.0✔✘✘
Stepuint321.0✔✘✘

IdentifyTime​

Indicates the remaining duration, in seconds, for which the device will continue self-identification. The range is 0 to 10 seconds with a step of 0.1. When the value is 0, the default remaining duration is used.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✘✔
Maxfloat10.0✔✘✘
Minfloat0.0✔✘✘
Stepuint320.1✔✘✘

HomeStationCredentials​

Home Station Credentials information.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueHomeStationCredentialsTraitPresentValueStructure✔✘✔

WiFiChannel​

Wi-Fi channel, such as channels 1–14 in the 2.4 GHz band or channels 149, 153, 157, 161, and 165 in the 5 GHz band.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint16✔✘✔
Maxuint16165.0✔✘✘
Minuint161.0✔✘✘
Stepuint321.0✔✘✘

ChildDeviceProvisioningState​

Used by the gateway to report the network-commissioning window state for child devices, such as Zigbee or Matter devices. The gateway reports “entered commissioning state” when it opens the network for a type of child device, and “exited commissioning state” when it closes that type of commissioning window. Higher-level applications use this to determine in real time whether the gateway allows a given type of child device to be added, guiding the user or showing commissioning progress.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueChildDeviceProvisioningStateEnum80✔✘✔
Supported Valueslist[ChildDeviceProvisioningStateEnum8]✔✘✘
Default Valueuint80✔✔✘

ZigbeeDiagnostics​

Provides diagnostic information for the Zigbee network, including the radio channel, extended PAN ID, network key, network name, PAN ID, RSSI (when available), and LQI (link quality indicator).

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueZigbeeDiagnosticsTraitPresentValueStructure✔✘✔

ZigbeeAuthRandcode​

A random number issued by the cloud when a Zigbee 3.0 device connects to the cloud for authentication.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✘✔✘

ZigbeeAuthRandcodeResponse​

The Confirm result returned when a Zigbee 3.0 device authenticates with the cloud.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✘✘✔

WiFiDiagnostics​

Provides diagnostic information for the Wi-Fi network, including the BSSID, encryption type, Wi-Fi version, channel, RSSI, network name, IPv4 address, IPv6 address, subnet mask, gateway, DNS, and backup DNS (available fields vary).

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueWiFiDiagnosticsTraitPresentValueStructure✔✘✔

MagicPairKeychain​

Used for the MagicPair network commissioning keychain.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

SupportedNetwork​

Indicates the network protocols supported by the device for MagicPair network joining. The value is a bit mask: bit0 = Wi-Fi, bit1 = Thread, bit2 = Ethernet, bit3 = Zigbee, bit4 = BLE, bit5 = BLE Endpoint, bit6 = Wi-Fi Endpoint, and bit7 = Wi-Fi Endpoint of a Limited Home Station. BLE used for pairing is not included.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint8✔✘✘
Maxuint8255.0✔✘✘
Minuint80.0✔✘✘
Stepuint321.0✔✘✘

SlaveAddress​

The address assigned to the device as a slave on a bus, used for master-slave communication addressing.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint8255✔✔✔
Maxuint8255.0✔✘✘
Minuint81.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint8255✔✔✘

ThreadDiagnostics​

Provides diagnostic information for the Thread network, including the channel, extended PAN ID, network key, network name, PAN ID, PSKc, active timestamp, security policy, operational dataset, RSSI, LQI, border agent ID, mesh-local prefix, commissioner credential, OpenThread version, and role (border router, leader, router, end device, sleepy end device, or router-eligible end device).

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueThreadDiagnosticsTraitPresentValueStructure✔✘✔

AuthenticationStatus​

Indicates the device authentication status, including whether authentication has passed and whether the certificate is valid.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueAuthenticationStatusEnum80✔✘✔
Supported Valueslist[AuthenticationStatusEnum8]✔✘✘
Default Valueuint80✔✔✘

WiFiRSSI​

A metric of Wi-Fi connection signal strength, measured in dBm, ranging from -100 dBm (very weak) to 0 dBm (strongest).

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueint8✔✘✔
Maxint80.0✔✘✘
Minint8-100.0✔✘✘
Stepuint321.0✔✘✘

CurrentTemperature​

Indicates the current temperature.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat26✔✘✔
Maxfloat100.0✔✘✘
Minfloat-50.0✔✘✘
Stepuint320.01✔✘✘
Default Valuefloat26✔✔✘

SetTemperatureLevel​

SetTemperatureLevel allows users to adjust the temperature to a preset level. The Supported Values parameter indicates the list of supported levels.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint80✔✔✔
Maxuint8255.0✔✘✘
Minuint80.0✔✘✘
Stepuint321.0✔✘✘
Supported Valueslist[characterString]✔✘✘
Default Valueuint80✔✔✘

SetTemperature​

SetTemperature allows users to specify and adjust the target temperature of a device or system.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat20✔✔✔
Maxfloat100.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat20✔✔✘

PackageRecognitionReport​

Automatically reports an event when a package is delivered, removed, or changes state.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuePackageRecognitionReportEnum8✘✘✔
Supported Valueslist[PackageRecognitionReportEnum8]✔✘✘

FaceIDReport​

A unique identifier associated with a specific face, used for facial recognition or authentication.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint64✘✘✔
Maxuint641.8446744E19✔✘✘
Minuint640.0✔✘✘
Stepuint321.0✔✘✘

HoldTime​

Unoccupied-state determination delay.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint161✔✔✔
Minuint161.0✔✘✘
Default Valueuint161✔✔✘

ActivityDetected​

Indicates whether any human activity is detected while a space is occupied.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean0✘✘✔
Default Valueboolean0✔✔✘

PresenceConfiguration​

Used to configure occupancy and vacancy software-sensor settings.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuePresenceConfigurationTraitPresentValueStructure✔✔✔

Presence​

Presence detects whether a person is in the monitored area.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuePresenceEnum80✔✘✔
Supported Valueslist[PresenceEnum8]✔✘✘
Default Valueuint80✔✔✘

HumanRecognitionReport​

Reports whether a human figure is detected in the defined detection area.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueHumanRecognitionReportEnum8✘✘✔
Supported Valueslist[HumanRecognitionReportEnum8]✔✘✘

AirQuality​

AirQuality indicates the air-quality level.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueAirQualityEnum80✔✘✔
Supported Valueslist[AirQualityEnum8]✔✘✘
Default Valueuint80✔✔✘

VOCQuality​

Indicates the volatile organic compound (VOC) air-quality level. Values: 0 = unknown, 1 = excellent, 2 = good, 3 = moderate, 4 = poor, 5 = very poor.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueVOCQualityEnum8✔✘✔
Supported Valueslist[VOCQualityEnum8]✔✘✘

VOCDensity​

This trait is used to access and report VOC concentration data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat1✔✘✔
Maxfloat9999.0✔✘✘
Minfloat1.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat1✔✔✘

AttitudeDetected​

This trait is used to access and report posture-detection data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueAttitudeDetectedEnum8✔✘✔
Supported Valueslist[AttitudeDetectedEnum8]✔✘✘

TripTime​

Indicates the motor travel time, in seconds, required to move from fully open to fully closed, or vice versa. The range is 1 to 300 seconds, with a default of 10 seconds.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✘✔
Maxfloat300.0✔✘✘
Minfloat1.0✔✘✘
Stepuint321.0✔✘✘

TargetPositionPercentage​

This trait is used to access and report target position percentage data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat50✔✔✔
Maxfloat100.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat50✔✔✘

CurrentPositionPercentage​

Indicates the actual position as a percentage from 0% to 100%, with a default step of 1%.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat50✔✘✔
Maxfloat100.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat50✔✔✘

Binding​

Binding represents a persistent relationship between an endpoint and one or more other local or remote endpoints.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuelist[BindingTraitPresentValueStructure]✔✔✔

SupportedBindingDeviceTypes​

Indicates the list of device types to which this controller endpoint can bind.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuelist✔✘✔

SupportedBindingFunctions​

Indicates the list of functions to which this controller endpoint can bind and control.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuelist✔✘✔

Feed​

This trait is used to access and report feeding-related data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueFeedEnum8✔✘✔
Supported Valueslist[FeedEnum8]✔✘✘

LocalControlDisabled​

Describes whether the button disables its associated local device-control function, such as relay control. When disabled, pressing the button cannot turn the local actuator on or off.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✔✔

ButtonEvent​

This trait is used to access and report button-event data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueButtonEventEnum8✘✘✔
Supported Valueslist[ButtonEventEnum8]✔✘✘

OutputSwitchingType​

Defines the type of external switch connected to the device.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueOutputSwitchingTypeEnum8✔✔✔
Supported Valueslist[OutputSwitchingTypeEnum8]✔✘✘

OnOff​

Writing turns the camera device on or off. Reading indicates the current power state. Values: false = off, true = on.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✔✔

OutputInterlockFlag​

When the values of two attributes are the same, the states represented by those attributes are interlocked.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint80✔✔✔
Maxuint8255.0✔✘✘
Minuint80.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint80✔✔✘

OutputNodeMode​

Defines the operating mode of the output node.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueOutputNodeModeEnum32✔✔✔
Supported Valueslist[OutputNodeModeEnum32]✔✘✘

StartUpOnOff​

Defines the startup behavior of a set of custom configuration parameters when the device is powered on, such as restoring user-defined settings. It may override the default OnOff behavior.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueStartUpOnOffEnum8✔✔✔
Supported Valueslist[StartUpOnOffEnum8]✔✘✘

IRKey​

This trait is used to access and report infrared-command data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueIRKeyEnum32✘✔✘
Supported Valueslist[IRKeyEnum32]✔✘✘

IRType​

Defines the device type of the IR remote control.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueIRTypeEnum8✔✔✔
Supported Valueslist[IRTypeEnum8]✔✘✘

CoolingTemperature​

Indicates the cooling temperature.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat26✔✔✔
Maxfloat100.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat26✔✔✘

CurrentHumidity​

This trait is used to access and report humidity data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat50✔✘✔
Maxfloat100.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat50✔✔✘

CurrentTemperature​

Indicates the current temperature.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat26✔✘✔
Maxfloat100.0✔✘✘
Minfloat-50.0✔✘✘
Stepuint320.01✔✘✘
Default Valuefloat26✔✔✘

Preset​

This trait is used to access and report preset data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuelist[PresetTraitPresentValueStructure]✔✔✔

SetBack​

Indicates the thermostat temperature setback range.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✔✔
Maxfloat25.5✔✘✘
Minfloat0.0✔✘✘
Stepuint320.1✔✘✘

PresetTypes​

This trait is used to access and report preset-type data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuelist✔✔✔

HeaterCoolerMode​

This trait is used to access and report heating/cooling mode data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueHeaterCoolerModeEnum8✔✔✔
Supported Valueslist[HeaterCoolerModeEnum8]✔✘✘

ActivePresetHandle​

This trait is used to access and report active preset handle data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterStringnull✔✔✔
Default ValuecharacterStringnull✔✔✘

HeatingTemperature​

Indicates the heating temperature.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat18✔✔✔
Maxfloat100.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat18✔✔✘

NumberOfPresets​

This trait is used to access and report preset-count data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint80✔✔✔
Minuint80.0✔✘✘
Default Valueuint80✔✔✘

HeaterCoolerButtonEvent​

An event triggered by button interaction on a thermostat or climate-control device.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueHeaterCoolerButtonEventEnum8✔✘✔
Supported Valueslist[HeaterCoolerButtonEventEnum8]✔✘✘

MinHeatCoolDeadBand​

Indicates the minimum difference between heating and cooling temperatures in automatic mode.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat2✔✔✔
Maxfloat2.5✔✘✘
Minfloat0.0✔✘✘
Stepuint320.1✔✘✘
Default Valuefloat2✔✔✘

CurrentTemperatureCalibration​

Used as a compensation/calibration offset for local temperature readings. Writing a positive or negative value corrects sensor deviation.

Specification mapping: corresponds to Matter LocalTemperatureCalibration; value = temperature in Celsius * 10. The current Function specification source (HeaterCooler) does not yet define an independent Trait ID, so the following parameters are organized according to the master table and mapping convention.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuenumber✔✔✔

TemperatureUIDisplayMode​

This trait specifies the unit used to display temperature on the thermostat's built-in screen.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueTemperatureUIDisplayModeEnum80✔✔✔
Supported Valueslist[TemperatureUIDisplayModeEnum8]✔✘✘
Default Valueuint80✔✔✘

AntiFreezeTemperature​

The anti-freeze protection temperature setting usually specifies the threshold that triggers the anti-freeze mechanism, for example, 5 °C.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat5✔✔✔
Maxfloat15.0✔✘✘
Minfloat5.0✔✘✘
Stepuint320.5✔✘✘
Default Valuefloat5✔✔✘

HeaterCoolerPolarity​

Specifies the polarity configuration used to determine whether the system controls cooling or heating.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueHeaterCoolerPolarityEnum82✔✔✔
Supported Valueslist[HeaterCoolerPolarityEnum8]✔✘✘
Default Valueuint82✔✔✘

TiltAngleDeviation​

Indicates the actual change (offset) in Tilt angle during the current movement.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✘✔
Maxfloat180.0✔✘✘
Minfloat-180.0✔✘✘
Stepuint320.01✔✘✘

StationaryState​

The Present Value of this trait indicates as an enumeration whether the target is currently stationary. A value of 0 indicates that the target is moving; a value of 1 indicates that it is stationary.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueStationaryStateEnum81✔✘✔
Supported Valueslist[StationaryStateEnum8]✔✘✘
Default Valueuint81✔✔✘

InitialTiltAngle​

Indicates the initial tilt angle established during device calibration, representing the angle between the calibration direction, such as upward, and the positive direction of the nearest axis.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✘✔
Maxfloat180.0✔✘✘
Minfloat-180.0✔✘✘
Stepuint320.01✔✘✘

EventReportInterval​

Indicates the interval, in seconds, between consecutive event reports from the device. For example, a value of 60 means that the device reports an event every 60 seconds. This interval determines how often the device sends event data to the gateway or cloud.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint3260✔✔✔
Maxuint32300.0✔✘✘
Minuint325.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint3260✔✔✘

ObjectOrientationEnable​

Enables or disables object-orientation monitoring. When set to True, the device actively monitors and reports object-orientation changes; when set to False, orientation monitoring is disabled.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean1✔✔✔
Default Valueboolean1✔✔✘

StationaryTiltAngle​

Indicates the tilt angle when an object becomes stationary after moving.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✘✔
Maxfloat180.0✔✘✘
Minfloat-180.0✔✘✘
Stepuint320.01✔✘✘

PeakTiltAngle​

Indicates the maximum tilt angle recorded between wake-up and becoming stationary.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✘✔
Maxfloat180.0✔✘✘
Minfloat-180.0✔✘✘
Stepuint320.01✔✘✘

ObjectMotionDetectionEnable​

Enables or disables object-motion detection. True indicates enabled (object movement will be detected); False indicates disabled.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean1✔✔✔
Default Valueboolean1✔✔✘

ObjectOrientationState​

Indicates the object's current spatial orientation detected by the device. The value is an enumeration representing the object's pose relative to the reference plane. Possible states are:

1 – Horizontal Up (the object faces up, for example, lying flat on a table with its front side up)

2 – Horizontal Down (the object faces down, for example, lying flat on a table with its front side down)

3 – Vertical (the object is upright, for example, perpendicular to the ground)

4 – Tilted (the object is inclined and is neither horizontal nor vertical)

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueObjectOrientationStateEnum8✔✘✔
Supported Valueslist[ObjectOrientationStateEnum8]✔✘✘

VibrationEvent​

This trait is used to access and report motion-sensor events.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueVibrationEventEnum8✘✘✔
Supported Valueslist[VibrationEventEnum8]✔✘✘

CubeWorkModeSetting​

Enables multiple operating-mode settings for Magic Cube devices to improve the user experience and interaction.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueCubeWorkModeSettingEnum80✔✔✔
Supported Valueslist[CubeWorkModeSettingEnum8]✔✘✘
Default Valueuint80✔✔✘

TopFace​

Indicates the face currently pointing upward on the cube controller, used to define the device state.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueTopFaceEnum8✔✘✔
Supported Valueslist[TopFaceEnum8]✔✘✘

CubeEvent​

This trait is used to access and report cube-event data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueCubeEventEnum8✘✘✔
Supported Valueslist[CubeEventEnum8]✔✘✘

TopFaceChanged​

Indicates that the device's “top face” has changed. Triggered when the user flips the device, such as a cube controller.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueTopFaceChangedEnum8✘✘✔
Supported Valueslist[TopFaceChangedEnum8]✔✘✘

HoldRotationInterval​

The duration of a hold-to-rotate event, that is, the rotation interval.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint16✘✘✔
Maxuint1665535.0✔✘✘
Minuint161.0✔✘✘
Stepuint321.0✔✘✘

RotationEvent​

Describes the knob event type: Rotate, Hold to rotate, or Inverted rotate. Values: 0 = Rotate, 1 = Hold to rotate, 2 = Inverted Rotate.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueRotationEventEnum8✘✘✔
Supported Valueslist[RotationEventEnum8]✔✘✘

RotationDirection​

Describes the rotation direction. Values: 0 = Clockwise, 1 = Counterclockwise.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueRotationDirectionEnum8✘✘✔
Supported Valueslist[RotationDirectionEnum8]✔✘✘

InvertedRotationAngle​

The angle of inverted rotation.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✘✘✔
Maxfloat3600.0✔✘✘
Minfloat-3600.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat0✔✔✘

RotationAngle​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✘✘✔
Maxfloat3600.0✔✘✘
Minfloat-3600.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat0✔✔✘

RotationInterval​

The duration of a rotation event, that is, the rotation interval.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint16✘✘✔
Maxuint1665535.0✔✘✘
Minuint161.0✔✘✘
Stepuint321.0✔✘✘

HoldRotationAngle​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✘✘✔
Maxfloat3600.0✔✘✘
Minfloat-3600.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat0✔✔✘

BinaryOutputPV​

BinaryOutputPV stores the command or actual on/off state of a binary output.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean0✔✔✔
Default Valueboolean0✔✔✘

AnalogInputPV​

AnalogInputPV conveys the real-time value of an analog input channel and its engineering metadata.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✘✔

TargetPlaybackState​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueTargetPlaybackStateEnum8✔✔✔
Supported Valueslist[TargetPlaybackStateEnum8]✔✘✘

MediaInformation​

Describes media information, such as the title and artist.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

PlaybackDuration​

Indicates the playback duration in ms.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✘✔
Maxfloat7200000.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘

CurrentPlaybackState​

Describes the current playback state.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueCurrentPlaybackStateEnum8✔✘✔
Supported Valueslist[CurrentPlaybackStateEnum8]✔✘✘

PlaybackMode​

Describes the current playback mode.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuePlaybackModeEnum8✔✔✔
Supported Valueslist[PlaybackModeEnum8]✔✘✘

SampledPosition​

Indicates or sets the current media playback position. The value is a time offset in milliseconds (ms), from 0 to the total playback duration. When written, the device seeks to this position.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✘✔
Maxfloat7200000.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘

LoginState​

Describes the login state of the media service.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

PlaybackSampledPosition​

Sets and queries the current playback position.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint64✔✔✔
Maxuint644.294967295E9✔✘✘
Minuint640.0✔✘✘
Stepuint321.0✔✘✘

SelectedMediaOutputSource​

Describes the selected media output source.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueSelectedMediaOutputSourceEnum8✔✔✔
Supported Valueslist[SelectedMediaOutputSourceEnum8]✔✘✘

SelectedSource​

Indicates or sets the currently selected media output source, such as the built-in speaker, Bluetooth, AUX, or HDMI. Values: 0 = Internal, 1 = Bluetooth, 2 = Aux, 3 = SPDIF, 4 = Coaxial, 5–7 = Audio 1–3, 8–10 = AV1–3, 11–13 = HDMI1–3, 14 = Other.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueSelectedSourceEnum8✔✔✔
Supported Valueslist[SelectedSourceEnum8]✔✘✘

MediaInput​

MediaInput provides a list of available input sources and commands for selecting and renaming them.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueenum8✔✔✔

FlameDetected​

Enables the device to detect open flames or flame characteristics in the monitored area. When a suspected flame is detected, an event is automatically triggered and reported.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueFlameDetectedEnum8✘✘✔
Supported Valueslist[FlameDetectedEnum8]✔✘✘

OperationalError​

OperationalError indicates that the device or system cannot perform its intended function.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueOperationalErrorEnum160✔✘✔
Supported Valueslist[OperationalErrorEnum16]✔✘✘
Default Valueuint160✔✔✘

OperationalState​

OperationalState indicates the current functional or operating state of the device, including whether it is active or idle.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueOperationalStateEnum160✔✘✔
Supported Valueslist[OperationalStateEnum16]✔✘✘
Default Valueuint160✔✔✘

RefrigeratorAlarm​

RefrigeratorAlarm indicates the current refrigerator alarm state.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuelist✔✘✔

CurrentMode​

CurrentMode represents the device’s current operating state or setting; values come from a predefined set of options.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueenum80✔✘✔
Default Valueenum80✔✔✘

ChangeToModeResponse​

ChangeToModeResponse is a response message or status indicating the result of a request to switch the device to a specific mode.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueChangeToModeResponseEnum160✔✘✔
Supported Valueslist[ChangeToModeResponseEnum16]✔✘✘
Default Valueuint160✔✔✘

BridgeDeviceID​

Represents the DeviceID of the Bridge device connected to this bridged node. String(32).

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✔✔

MultiStateInputPV​

MultiStateInputPV provides the current enumerated state, a human-readable state label, and optional descriptive text.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint32✔✘✔

PulseDuration​

Defines the pulse duration for a pulsed load.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint16✔✔✔
Maxuint1665535.0✔✘✘
Minuint160.0✔✘✘
Stepuint321.0✔✘✘

LoadType​

Describes the type of load connected to the switch. 0: General, 1: Linkable, 2: Pulsed.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueLoadTypeEnum8✔✔✔
Supported Valueslist[LoadTypeEnum8]✔✘✘

ThemeID​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint161✔✘✔
Minuint161.0✔✘✘
Default Valueuint161✔✔✘

MaxPageNum​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint161✔✘✔
Default Valueuint161✔✔✘

ScreenWidth​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint16240✔✘✔
Default Valueuint16240✔✔✘

DataVersion​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint640✔✘✔
Default Valueuint640✔✔✘

ThemeVersion​

Theme version.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint161✔✘✔
Maxuint1699999.0✔✘✘
Minuint161.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint161✔✔✘

ScreenHeight​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint16240✔✘✔
Default Valueuint16240✔✔✘

EnableIndicator​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuetlv✔✔✔

StartUpOnOff​

Defines the startup behavior of a set of custom configuration parameters when the device powers on, such as restoring user-defined settings. It may override the default OnOff behavior.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueStartUpOnOffEnum8✔✔✔
Supported Valueslist[StartUpOnOffEnum8]✔✘✘

Condition​

Represents the remaining filter life as a percentage.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat100✔✘✔
Maxfloat100.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat100✔✔✘

ChangeIndication​

ChangeIndication defines the filter-life status.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueChangeIndicationEnum80✔✘✔
Supported Valueslist[ChangeIndicationEnum8]✔✘✘
Default Valueuint80✔✔✘

FilterType​

FilterType defines the filter type.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueFilterTypeEnum8✔✘✔
Supported Valueslist[FilterTypeEnum8]✔✘✘

WindSetting​

WindSetting defines the airflow type.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueWindSettingEnum80✔✔✔
Supported Valueslist[WindSettingEnum8]✔✘✘
Default Valueuint80✔✔✘

AirflowDirection​

AirflowDirection defines the airflow direction.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueAirflowDirectionEnum80✔✔✔
Supported Valueslist[AirflowDirectionEnum8]✔✘✘
Default Valueuint80✔✔✘

FanMode​

FanMode defines the fan mode.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueFanModeEnum8✔✔✔
Supported Valueslist[FanModeEnum8]✔✘✘

FanSpeed​

FanSpeed represents the fan speed as a percentage.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint8✔✔✔
Maxuint8100.0✔✘✘
Minuint80.0✔✘✘
Stepuint321.0✔✘✘

RockSetting​

Defines the oscillation mode.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueRockSettingEnum80✔✔✔
Supported Valueslist[RockSettingEnum8]✔✘✘
Default Valueuint80✔✔✘

HeartRate​

Measures heartbeats per minute in real time.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✘✔
Maxfloat300.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat0✔✔✘

CurrentPressure​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat101✔✘✔
Maxfloat200000.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat101✔✔✘

MultiStateOutputPV​

MultiStateOutputPV contains the requested or currently active enumerated output state.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint32✔✔✔

ContactSensorState​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✘✔

OpenAngle​

Door or window opening angle.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✘✔
Maxfloat360.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat0✔✔✘

Volume​

Indicates or sets the camera device speaker volume, such as for two-way audio. The value is typically a percentage (0 to 100) or a device-defined numeric range.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat50✔✔✔
Maxfloat100.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat50✔✔✘

WaterFreezeDetector​

Note: WaterFreezeDetector is a Function (water freeze detector) in the specification source, not an independent Trait. This Function contains only the BooleanState Trait.

Used to detect the risk of freezing in pipes or the environment and report water-freeze-related events when a threshold is reached. The Boolean state is represented by BooleanState.

StepValue​

Indicates or sets the step increment, such as for volume adjustment. When written, it defines the amount changed by a single step. Units and ranges vary by device.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✔✔
Maxfloat100.0✔✘✘
Minfloat1.0✔✘✘
Stepuint3210.0✔✘✘

Mute​

Indicates the speaker mute state.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✔✔

LockOperation​

Records and reports a lock operation event when the device is successfully unlocked or locked by any supported method. It provides detailed context for the operation, including its source (such as the Matter ecosystem or a local method), the user identity, and the specific credential used.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueLockOperationTraitPresentValueStructure✘✘✔

LockOperationError​

When a door-lock operation fails for any reason, the lock emits a LockOperationError event.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueLockOperationErrorTraitPresentValueStructure✘✘✔

SupportedRemoteFeatures​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✘

NumberOfCredentialsSupportedPerUser​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint80✔✘✔
Default Valueuint80✔✔✘

NumberOfTotalUsersSupported​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint160✔✘✔
Default Valueuint160✔✔✘

DoorState​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueDoorStateEnum8✔✘✔
Supported Valueslist[DoorStateEnum8]✔✘✘

NumberOfYearDaySchedulesSupportedPerUser​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint80✔✘✔
Default Valueuint80✔✔✘

LockState​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueLockStateEnum8✔✘✔
Supported Valueslist[LockStateEnum8]✔✘✘

EnableRemoteControl​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✔✔

NumberOfPINUsersSupported​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint160✔✘✔
Default Valueuint160✔✔✘

LockUserChange​

When a door-lock user, schedule, or credential changes, the lock emits a LockUserChange event.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueLockUserChangeTraitPresentValueStructure✘✘✔

RemoteControlWithAuthCode​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✘✔✘

DoorLockAlarm​

The door lock can send several alarms when critical conditions occur.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueDoorLockAlarmTraitPresentValueStructure✘✘✔

RemoteUnlock​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✔✔

NumberOfRFIDUsersSupported​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint160✔✘✔
Default Valueuint160✔✔✘

NumberOfWeekDaySchedulesSupportedPerUser​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint80✔✘✔
Default Valueuint80✔✔✘

CO2Level​

Indicates the carbon dioxide concentration level using a qualitative index. Values: 0 = Excellent (normal/low CO2), 1 = Light Pollution (slightly elevated CO2), 2 = Heavy Pollution (high CO2 concentration).

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueCO2LevelEnum8✔✘✔
Supported Valueslist[CO2LevelEnum8]✔✘✘

CO2Density​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✘✔
Maxfloat9999.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat0✔✔✘

VacuumOperationalError​

VacuumOperationalError indicates the specific error type encountered when the device or system cannot perform its intended function.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueVacuumOperationalErrorEnum160✔✘✔
Supported Valueslist[VacuumOperationalErrorEnum16]✔✘✘
Default Valueuint160✔✔✘

VacuumOperationalState​

VacuumOperationalState indicates the current operating state or mode of the vacuum device.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueVacuumOperationalStateEnum160✔✘✔
Supported Valueslist[VacuumOperationalStateEnum16]✔✘✘
Default Valueuint160✔✔✘

CurrentValveState​

CurrentValveState represents the valve’s current operating state.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueCurrentValveStateEnum8✔✘✔
Supported Valueslist[CurrentValveStateEnum8]✔✘✘

DefaultOpenDuration​

DefaultOpenDuration represents the default duration, in seconds, that the valve remains open when the OpenDuration field is not specified.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat1✔✔✔
Maxfloat100000.0✔✘✘
Minfloat1.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat1✔✔✘

RemainingDuration​

RemainingDuration indicates the time remaining before the valve automatically closes.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✔✔
Maxfloat100000.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat0✔✔✘
Is NullbooleanFalse✔✔✔

ScreenBrightness​

Controls the screen brightness level, with values from 1% to 100%.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat50✔✔✔
Maxfloat100.0✔✘✘
Minfloat1.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat50✔✔✘

SamplingInterval​

Defines the data sampling interval.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat5✔✔✔
Maxfloat3600.0✔✘✘
Minfloat0.5✔✘✘
Stepuint320.1✔✘✘
Default Valuefloat5✔✔✘

CurrentIlluminance​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat50✔✘✔
Maxfloat100000.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat50✔✔✘

CameraActiveStatus​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✔✔

CameraRTSPURL​

Indicates the camera RTSP (Real Time Streaming Protocol) URL for accessing the live video stream through RTSP. This property returns a JSON object whose keys are resolution identifiers, such as "360p", "720p", "1080p", and "4mp", and whose values are the corresponding complete RTSP URL strings. Example: {"360p": "rtsp://192.168.1.109:8554/360p","720p": "rtsp://192.168.1.109:8554/720p","1080p": "rtsp://192.168.1.109:8554/1080p","4mp": "rtsp://192.168.1.109:8554/4mp"}

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

P2PCaptureStatus​

P2P animated snapshot status switch.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✔✔

CameraRTSPEnable​

Indicates the camera RTSP (Real Time Streaming Protocol) enable-switch configuration. When enabled, the live video stream can be accessed through RTSP; when disabled, RTSP access is blocked.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean0✔✔✔
Default Valueboolean0✔✔✘

P2PCaptureEnabled​

Indicates whether the camera has P2P (peer-to-peer) snapshot capture enabled.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean1✔✘✔
Default Valueboolean1✔✔✘

CurrentSensitivityLevel​

Indicates the currently selected general-configuration sensitivity level.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint8✔✔✔
Maxuint8255.0✔✘✘
Minuint80.0✔✘✘
Stepuint321.0✔✘✘

GasDensity​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✘✔
Maxfloat100.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat0✔✔✘

SelfCheck​

Enables self-checks to verify that device functions are operating normally.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean0✔✔✔
Default Valueboolean0✔✔✘

Mute​

Indicates the speaker mute state.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✔✔

GasDetected​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✘✔

GestureRecognitionReport​

Enables the device to recognize specific user gestures through visual sensors. When a predefined gesture is detected, the corresponding gesture event is automatically reported.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueGestureRecognitionReportEnum16✘✘✔
Supported Valueslist[GestureRecognitionReportEnum16]✔✘✘

BreathingMonitoring​

Note: BreathingMonitoring is a Function (breathing monitoring) in the specification source, not an independent Trait. This Function contains only the BreathingRate Trait.

Uses sensors to continuously or periodically measure the user’s breathing rate and pattern for health monitoring. See BreathingRate for the real-time breathing rate.

BreathingRate​

Measures breaths per minute in real time.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✘✔
Maxfloat60.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat0✔✔✘

CharStringValuePV​

Indicates the current value of the CharacterString Value Object.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✔✔

SweeperState​

This Trait provides access to and reporting for the associated data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueSweeperStateEnum8✔✘✔
Supported Valueslist[SweeperStateEnum8]✔✘✘

EvseSupplyState​

EvseSupplyState represents the current power supply state of the electric vehicle supply equipment (EVSE).

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueEvseSupplyStateEnum32✔✘✔
Supported Valueslist[EvseSupplyStateEnum32]✔✘✘

MinChargeCurrent​

MinChargeCurrent indicates the minimum current level at which the electric vehicle can charge.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✘✔
Maxfloat10000.0✔✘✘
Minfloat0.0✔✘✘
Stepuint320.001✔✘✘
Default Valuefloat0✔✔✘

EvseState​

EVSEState represents the current state of the electric vehicle supply equipment (EVSE).

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueEvseStateEnum32✔✘✔
Supported Valueslist[EvseStateEnum32]✔✘✘

ChargingEnabledUntil​

ChargingEnabledUntil indicates the time until which charging of the electric vehicle (EV) or device is allowed.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat6✔✘✔
Maxfloat10000.0✔✘✘
Minfloat0.0✔✘✘
Stepuint320.001✔✘✘
Default Valuefloat6✔✔✘
Is NullbooleanFalse✔✘✔

BatteryCapacity​

BatteryCapacity is the total electrical energy that a battery can store, typically measured in kilowatt-hours.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✘✔
Maxfloat10000.0✔✘✘
Minfloat0.0✔✘✘
Stepuint320.001✔✘✘
Default Valuefloat0✔✔✘

VehicleID​

VehicleID is the unique identifier assigned to each electric vehicle (EV).

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuestring32✔✘✔

EvseFaultState​

EvseFaultState represents the current fault state of the electric vehicle supply equipment (EVSE).

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueEvseFaultStateEnum32✔✘✔
Supported Valueslist[EvseFaultStateEnum32]✔✘✘

BatPercentRemaining​

Indicates the remaining battery percentage.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat50✔✘✔
Maxfloat100.0✔✘✘
Minfloat0.0✔✘✘
Stepuint320.1✔✘✘
Default Valuefloat50✔✔✘

MaxChargeCurrent​

MaxChargeCurrent indicates the maximum current level at which the electric vehicle can charge.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✘✔
Maxfloat10000.0✔✘✘
Minfloat0.0✔✘✘
Stepuint320.001✔✘✘
Default Valuefloat0✔✔✘

CurrentFlow​

CurrentFlow represents the current flow value in m³/h.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✘✔
Maxfloat65535.0✔✘✘
Minfloat0.0✔✘✘
Stepuint320.01✔✘✘
Default Valuefloat0✔✔✘

ExpressedState​

ExpressedState defines the alarm state.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueExpressedStateEnum80✔✘✔
Supported Valueslist[ExpressedStateEnum8]✔✘✘
Default Valueuint80✔✔✘

CODetected​

Indicates whether a carbon monoxide leak has been detected.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean0✔✘✔
Default Valueboolean0✔✔✘

BuiltInEffects​

This Trait contains a list of all built-in effects supported by the device. Each item includes an EffectID (0x00-0x7F) and a BuiltInEffectLabelID.

An empty list indicates that there are currently no built-in effects; a null value indicates that this information is currently unavailable.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuelist[BuiltInEffectsTraitPresentValueStructure]✔✘✔
Is NullbooleanFalse✔✘✔

MaxUserDefinedEffects​

This Trait indicates the maximum number of user-defined effects supported by the device.

When the number of effects reaches the limit, attempts to add a user-defined effect should return a capacity-related error.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint8✔✘✔
Maxuint832.0✔✘✘
Minuint81.0✔✘✘
Stepuint321.0✔✘✘

CurrentEffectID​

This Trait indicates the EffectID of the currently active effect; a null value indicates that no effect is currently active.

This value can be used to highlight the active effect in the user interface and as context for subsequent query, switch, or stop operations.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint8✔✘✔
Is NullbooleanFalse✔✘✔

EffectInfo​

This Trait provides a list of effect information. Each item includes an EffectID, EffectData, and EffectName for maintaining, displaying, and synchronizing effect details.

This Trait is maintained in the cloud and is not reported by the device.

The encoding of EffectData should remain consistent with the effect write and preview commands so that clients can display, back up, or reuse it directly after reading it.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuelist[EffectInfoTraitPresentValueStructure]✔✘✔

MaxEffectNameLength​

Indicates the maximum allowed byte length of the EffectName field in user-defined scenes for a window-covering device. This device-specific value ranges from 1 to 32.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint8✔✘✔
Maxuint832.0✔✘✘
Minuint81.0✔✘✘
Stepuint321.0✔✘✘

UserDefinedEffects​

This Trait contains a list of all user-defined effects currently stored on the device. Each item includes an EffectID (0x80-0xFE) and an EffectName.

An empty list indicates that there are currently no user-defined effects; a null value indicates that this information is currently unavailable, for example while the device is initializing or the data cannot yet be read.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuelist[UserDefinedEffectsTraitPresentValueStructure]✔✘✔

OnTransitionTime​

This Trait indicates the brightness transition duration when the On/Off Cluster on the same endpoint receives an On command.

The device should gradually transition CurrentLevel from the minimum brightness allowed by the device to the maximum brightness during this duration.

This value is measured in 0.1 s (one-tenth of a second). For example, a value of 10 represents a 1.0 s turn-on transition duration.

When this Trait is not implemented or Present Value is null, the device should fall back to the OnOffTransitionTime configuration.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueint320✔✔✔
Maxint324.294967295E9✔✘✘
Minint321.0✔✘✘
Stepuint321.0✔✘✘
Default Valueint320✔✔✘

CurrentLevel​

This Trait represents the current brightness level and is the core state value of Level Control.

On the Matter side (lighting devices), levels typically range from 1 to 254. Aqara uses percentage semantics, with example mappings of 1% ≈ 1, 50% ≈ 127, and 100% ≈ 254.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat50✔✔✔
Maxfloat100.0✔✘✘
Minfloat1.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat50✔✔✘
Maximum Actual Valuefloat✔✘✘
Minimum Actual Valuefloat✔✘✘

OffTransitionTime​

This Trait indicates the brightness transition duration when the On/Off Cluster on the same endpoint receives an Off command.

The device must gradually transition CurrentLevel from maximum brightness to the minimum brightness allowed by the device during this period (typically corresponding to the lights-off state).

This value is in units of 0.1 s (one tenth of a second). For example, a value of 10 represents a lights-off transition duration of 1.0 s.

When this Trait is not implemented or Present Value is null, the device must fall back to the OnOffTransitionTime configuration.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueint320✔✔✔
Maxint324.294967295E9✔✘✘
Minint321.0✔✘✘
Stepuint321.0✔✘✘
Default Valueint320✔✔✘

CurrentY​

This Trait represents the y component of the CIE 1931 chromaticity coordinates.

The relationship is y = CurrentY / 65536, and the valid range of CurrentY is 0–65279.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint16✔✔✔
Maxuint1665279.0✔✘✘
Minuint160.0✔✘✘
Stepuint321.0✔✘✘

ColorMode​

The ColorMode trait represents the color space currently used by a lighting device—the color encoding format or coordinate system the device uses to receive and report color data. It supports reading and reporting but not writing. It supports four values: Hue, XY, color temperature, and RGB. Hue describes color using hue, typically with saturation and brightness, and is suitable for intuitive color selection. XY provides an accurate, device-independent color description based on CIE 1931 chromaticity coordinates and is suitable for professional color management. Color temperature describes white light using a color-temperature value (in mireds, 1000000 / color temperature in Kelvin) to adjust its warmth or coolness. RGB describes colored light using red, green, and blue components, the most common full-color control method. ColorMode and LightingModeSetting are traits at different levels: LightingModeSetting determines the set of functions supported by the device (such as color-temperature or color support), which affects which data-model points are exposed, while ColorMode only determines the encoding format of current color data. They are independent but jointly affect the device's color-control behavior. In particular, when a light is a child device bridged through a gateway, the gateway automatically identifies its supported color spaces and updates its data model. Therefore, when an external system (such as an app or AI controller) controls a light's color, it should determine which color-control commands to send based on the traits and commands in the device data model (for example, whether color-temperature, RGB, or XY control commands are present). The gateway automatically adapts the color space and ultimately controls the child device.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueColorModeEnum8✔✘✔
Supported Valueslist[ColorModeEnum8]✔✘✘

WhitePointXY​

Defines the X and Y coordinates of the white point in the CIE 1931 chromaticity space, used to describe the device white-point reference.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueWhitePointXYPresentValueStructure✔✘✔

ColorTemperature​

This Trait is used to access and report the color-temperature value.

Implementations commonly convert between Kelvin and mireds: Mired = 1000000 / Kelvin.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint32270✔✔✔
Maxuint32370.0✔✘✘
Minuint32153.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint32270✔✔✘

LEDICQuantity​

Indicates the number of dimming-driver ICs.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint16✔✔✔
Maxuint1665535.0✔✘✘
Minuint160.0✔✘✘
Stepuint321.0✔✘✘

ColorRGB​

ColorRGB represents an RGB color value in the RGB color space.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint320✔✔✔
Maxuint321.6777215E7✔✘✘
Minuint320.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint320✔✔✘

ColorXY​

ColorXY represents x and y in the CIE 1931 color space.

The mapping is: the first two bytes correspond to CurrentX, and the last two bytes correspond to CurrentY; x = CurrentX / 65536 and y = CurrentY / 65536.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint320✔✔✔
Maxuint324.2949673E9✔✘✘
Minuint320.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint320✔✔✘

Hue​

Contains the current hue value of the light source, in degrees (0–360).

The conversion to and from Matter CurrentHue is Hue(deg) = CurrentHue * 360 / 254.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✔✔
Maxfloat360.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘

StartUpXYColor​

ColorXY represents x and y values in the CIE xyY color space and contains ColorX and ColorY elements, where x = ColorX / 65535 and y = ColorY / 65535.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint320✔✔✔
Maxuint324.2949673E9✔✘✘
Minuint320.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint320✔✔✘

LightingMusicSyncMode​

Determines how lighting responds to music when enabled, such as with random effects, breathing transitions, flowing rainbows, or water ripples.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueLightingMusicSyncModeEnum80✔✔✔
Supported Valueslist[LightingMusicSyncModeEnum8]✔✘✘
Default Valueuint80✔✔✘

StartUpColorTemperature​

Sets the default color temperature applied when the device powers on and the light is on.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint32270✔✔✔
Maxuint32370.0✔✘✘
Minuint32153.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint32270✔✔✘

LightingDynamicSceneMode​

Supports dynamic lighting effects such as flowing rainbows, breathing fades, and flashing, and provides preset scenes such as “Forward Rainbow” and “Waterfall” for rich visual experiences.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueLightingDynamicSceneModeEnum80✔✔✔
Supported Valueslist[LightingDynamicSceneModeEnum8]✔✘✘
Default Valueuint80✔✔✘

Saturation​

Contains the current saturation of the light source.

The conversion to and from Matter CurrentSaturation is Saturation(0~1) = CurrentSaturation / 254; it can be displayed as 0–100% in Aqara's percentage view.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat50✔✔✔
Maxfloat100.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat50✔✔✘

CurrentG​

This Trait is used to access and report green-value data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueint32✔✔✔
Maxint32255.0✔✘✘
Minint320.0✔✘✘
Stepuint321.0✔✘✘

CurrentB​

This Trait is used to access and report blue-value data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueint32✔✔✔
Maxint32255.0✔✘✘
Minint320.0✔✘✘
Stepuint321.0✔✘✘

LightingMusicSyncEnable​

Synchronizes lighting color and brightness with the rhythm of music for dynamic audiovisual effects.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean0✔✔✔
Default Valueboolean0✔✔✘

CurrentX​

This Trait represents the x component of the CIE 1931 chromaticity coordinates.

The relationship is x = CurrentX / 65536, and the valid range of CurrentX is 0–65279.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint16✔✔✔
Maxuint1665279.0✔✘✘
Minuint160.0✔✘✘
Stepuint321.0✔✘✘

ColorPointRGBXY​

Defines the coordinate points of the RGB primaries in the CIE 1931 chromaticity space (each of R/G/B includes X and Y), used to describe the boundaries of the device color gamut.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueColorPointRGBXYPresentValueStructure✔✘✔

LEDICProtocol​

Indicates the LED IC protocol.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueLEDICProtocolEnum8✔✔✔
Supported Valueslist[LEDICProtocolEnum8]✔✘✘

LEDType​

Indicates the LED package type.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueLEDTypeEnum8✔✔✔
Supported Valueslist[LEDTypeEnum8]✔✘✘

CurrentR​

This Trait is used to access and report red-value data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueint32✔✔✔
Maxint32255.0✔✘✘
Minint320.0✔✘✘
Stepuint321.0✔✘✘

MotorSpeedPercentage​

Defines the motor operating-speed percentage, ranging from 1 (lowest speed) to 100 (highest speed).

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat50✔✔✔
Maxfloat100.0✔✘✘
Minfloat1.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat50✔✔✘

WindowCoveringCategory​

Reported by curtain-type devices to classify window-covering devices into broad categories.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueWindowCoveringCategoryEnum80✔✘✔
Supported Valueslist[WindowCoveringCategoryEnum8]✔✘✘
Default Valueuint80✔✔✘

WindowCoveringMotorsBinding​

Indicates whether multiple motors in a curtain-type device are logically bound for unified control. Values: false = independent control; true = unified master control.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✔✔

UnconfiguredTravelControlPermission​

Indicates whether control is allowed when the curtain motor device travel is not configured.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean1✔✘✔
Default Valueboolean1✔✔✘

LimitPointSetting​

Used to configure curtain motor limit points, specifically the fully open or fully closed limit position.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueLimitPointSettingEnum8✔✔✔
Supported Valueslist[LimitPointSettingEnum8]✔✘✘

ObstacleLimitMarkingBlockTime​

The duration, in seconds, for which the obstacle limit-marking function is disabled.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint8255✔✔✔
Maxuint8255.0✔✘✘
Minuint810.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint8255✔✔✘

MotorSpeedSetting​

Defines the motor operating-speed level, ranging from 1 (lowest speed) to 2 (highest speed).

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueMotorSpeedSettingEnum81✔✔✔
Supported Valueslist[MotorSpeedSettingEnum8]✔✘✘
Default Valueuint81✔✔✘

ManualPullStartStopEnabled​

Enables users to manually start or stop curtain/window-covering movement by pulling.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean1✔✔✔
Default Valueboolean1✔✔✘

CurrentRotationAngle​

Present Value indicates the current rotation angle of the window-covering device, ranging from -90 to 90 degrees.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✘✔
Maxfloat90.0✔✘✘
Minfloat-90.0✔✘✘
Stepuint321.0✔✘✘

ObstacleLimitSensitivity​

The sensitivity setting when a curtain motor encounters an obstacle.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueObstacleLimitSensitivityEnum82✔✔✔
Supported Valueslist[ObstacleLimitSensitivityEnum8]✔✘✘
Default Valueuint82✔✔✘

TripTime​

Indicates the motor travel time—the time in seconds required to move from fully open to fully closed, or vice versa. The range is 1 to 300 seconds, with a default of 10 seconds.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✘✔
Maxfloat300.0✔✘✘
Minfloat1.0✔✘✘
Stepuint321.0✔✘✘

TravelConfigured​

Indicates whether the curtain motor travel (movement range) has been configured.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean0✔✘✔
Default Valueboolean0✔✔✘

CurrentPositionPercentage​

Identifies the actual position as a percentage from 0% to 100%, with a default step of 1%.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat50✔✘✔
Maxfloat100.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat50✔✔✘

MotorControllability​

Indicates whether the motor is currently controllable.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✘✔

MotorDirectionReversed​

Specifies whether the motor operating direction is reversed, affecting how the window covering opens and closes.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean0✔✔✔
Default Valueboolean0✔✔✘

WindowCoveringType​

Identifies the window-covering product type, such as roller shades, Venetian blinds, or curtains. The value is an enumeration defined in the supported-values list (0 = Roller Shade, 1 = Venetian Blind, …, 255 = Unknown).

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueWindowCoveringTypeEnum80✔✔✔
Supported Valueslist[WindowCoveringTypeEnum8]✔✘✘
Default Valueuint80✔✔✘

ObstacleLimitAutoReboundEnable​

When enabled, the curtain motor reverses direction upon encountering an obstacle to prevent damage.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean1✔✔✔
Default Valueboolean1✔✔✘

ManualPullEvent​

Tracks or emits events triggered by manual pull interactions with a window-covering device.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueManualPullEventEnum32✘✘✔
Supported Valueslist[ManualPullEventEnum32]✔✘✘

TargetPositionPercentage​

This Trait is used to access and report target-position percentage data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat50✔✔✔
Maxfloat100.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat50✔✔✘

TargetRotationAngle​

Present Value specifies the target rotation angle of the window-covering device, ranging from -90 to 90 degrees.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✔✔
Maxfloat90.0✔✘✘
Minfloat-90.0✔✘✘
Stepuint321.0✔✘✘

WindowCoveringOpenOrientation​

Identifies the actual window-covering opening direction for automatic control.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueWindowCoveringOpenOrientationEnum8✔✔✔
Supported Valueslist[WindowCoveringOpenOrientationEnum8]✔✘✘

MotorOperationStatus​

Indicates the motor's current operating state.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueMotorOperationStatusEnum82✔✘✔
Supported Valueslist[MotorOperationStatusEnum8]✔✘✘
Default Valueuint82✔✔✘

ManualPullStartEnabled​

Enables users to manually start curtain/window-covering movement by pulling.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean1✔✔✔
Default Valueboolean1✔✔✘

LimitPointCount​

Represents the number of limit points (or travel limits) configured for the curtain-type motor.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint80✔✘✔
Maxuint82.0✔✘✘
Minuint80.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint80✔✔✘

TargetPositionRotationPercentage​

The Present Value of the TargetPositionRotationPercentage trait represents, as a percentage in 1% units, the target tilt position the window-covering device will reach or is moving toward.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✔✔
Maxfloat100.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat0✔✔✘

CurrentPositionRotationPercentage​

The Present Value of the CurrentPositionRotationPercentage trait represents the actual tilt/rotation position as a percentage, ranging from 0% to 100% with a default step of 1%.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✘✔
Maxfloat100.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat0✔✔✘

ManualPullStopEnabled​

Enables users to manually stop curtain/window-covering movement by pulling.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean1✔✔✔
Default Valueboolean1✔✔✘

ObstacleLimitMarkingEnable​

Enables or disables marking a limit point (open or closed) when the motor encounters an obstacle.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean1✔✔✔
Default Valueboolean1✔✔✘

ManualPullAdaptiveSpeedEnabled​

Allows adaptive speed adjustment during manual pulling, providing pull-force-based variable-speed response.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean0✔✔✔
Default Valueboolean0✔✔✘

HoldTime​

Unoccupied determination delay.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint161✔✔✔
Minuint161.0✔✘✘
Default Valueuint161✔✔✘

DurationOccupiedWithinOneWeek​

Represents the total time, in milliseconds, that an occupancy sensor detects occupancy within a calendar week beginning Monday at 00:00:00.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✘✔
Maxfloat6.048E8✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘

Occupancy​

This Trait is used to access and report presence-status data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✘✔

DurationOccupiedWithinOneDay​

Represents the total time, in milliseconds, that an occupancy sensor detects occupancy within one day.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✘✔
Maxfloat8.64E7✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘

OccupancySensorType​

Specifies the occupancy-sensor type, such as PIR, ultrasonic, radar, or vision.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueOccupancySensorTypeEnum8✔✘✔
Supported Valueslist[OccupancySensorTypeEnum8]✔✘✘

BooleanState​

BooleanState describes how Boolean values are used in the device context, possibly in a smart-home system, to represent status information.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean0✔✘✔
Default Valueboolean0✔✔✘

ExpressedState​

ExpressedState defines the state of an alarm device.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueExpressedStateEnum80✔✘✔
Supported Valueslist[ExpressedStateEnum8]✔✘✘
Default Valueuint80✔✔✘

FireProductIdentification​

This Trait is used to access and report fire identification-code data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

SmokeDensitydB​

This Trait is used to access and report smoke-density dB data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✘✔
Maxfloat10.0✔✘✘
Minfloat0.0✔✘✘
Stepuint320.001✔✘✘
Default Valuefloat0✔✔✘

SmokeChamberContamination​

Indicates the contamination state of the smoke chamber. This Trait uses an enumeration to represent contamination levels caused by dust or particulate buildup obstructing the optical path. A nonzero value indicates maintenance is required, and higher values may indicate more severe contamination.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueSmokeChamberContaminationEnum80✔✘✔
Supported Valueslist[SmokeChamberContaminationEnum8]✔✘✘
Default Valueuint80✔✔✘

AlarmError​

This Trait is used to access and report alarm-error data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueAlarmErrorEnum8✔✔✔
Supported Valueslist[AlarmErrorEnum8]✔✘✘

SelfCheck​

Facilitates self-checks to verify that device functions operate correctly.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean0✔✔✔
Default Valueboolean0✔✔✘

SmokeState​

This Trait is used to access and report smoke-state data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueSmokeStateEnum8✔✘✔
Supported Valueslist[SmokeStateEnum8]✔✘✘

AlarmsEnabled​

This Trait is used to access and report alarm-enable data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✔✔

ContaminationState​

This Trait is used to access and report alarm-device contamination data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✔✔

Mute​

Indicates the speaker mute state.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✔✔

SmokeDensity​

This Trait is used to access and report smoke-density data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✘✔
Maxfloat5.0✔✘✘
Minfloat0.0✔✘✘
Stepuint320.001✔✘✘
Default Valuefloat0✔✔✘

SmokeDetected​

This Trait is used to access and report smoke-detection status data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✘✔

EnableHeartbeatIndicator​

This Trait is used to access and report heartbeat-indicator control data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean1✔✔✔
Default Valueboolean1✔✔✘

FreshAirMode​

This trait defines the fresh-air mode.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueFreshAirModeEnum80✔✔✔
Supported Valueslist[FreshAirModeEnum8]✔✘✘
Default Valueuint80✔✔✘

AnalogOutputPV​

AnalogOutputPV carries the commanded or actual value of an analog-output object.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat✔✔✔

MotionDetected​

This Trait is used to access and report motion-detection data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueMotionDetectedEnum8✘✘✔
Supported Valueslist[MotionDetectedEnum8]✔✘✘

PetRecognitionReport​

Enables smart devices to accurately identify pet types. When a cat, dog, or both are detected, the specific type is reported automatically.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuePetRecognitionReportEnum16✘✘✔
Supported Valueslist[PetRecognitionReportEnum16]✔✘✘

PM1.0Density​

This Trait is used to access and report PM1.0-density data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✘✔
Maxfloat65535.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat0✔✔✘

PM2.5Density​

This Trait is used to access and report PM2.5-density data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✘✔
Maxfloat1000.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat0✔✔✘

PM2.5Level​

This Trait is used to access and report PM2.5-level data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuePM2.5LevelEnum8✔✘✔
Supported Valueslist[PM2.5LevelEnum8]✔✘✘

PM10Density​

This Trait is used to access and report PM10-density data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✘✔
Maxfloat65535.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat0✔✔✘

AnomalySoundDetected​

This function enables the device to intelligently identify anomalous sounds in its environment. For example, when an event matching the characteristics of a baby crying is detected, a crying event is reported.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueAnomalySoundDetectedEnum8✘✘✔
Supported Valueslist[AnomalySoundDetectedEnum8]✔✘✘

RingtonePlayVolume​

Indicates the volume level for playing a ringtone or music. The range is 0 (muted) to 100 (maximum volume).

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat50✔✔✔
Maxfloat100.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat50✔✔✘

RingtonePlayIndex​

Indicates the index of the ringtone or music to play. This trait allows a specific audio track to be selected from a predefined list, with each index corresponding to a unique ringtone or music identifier. The value is an enumeration mapped to an audio file.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueRingtonePlayIndexEnum32✔✔✔
Supported Valueslist[RingtonePlayIndexEnum32]✔✘✘

RingtonePlayStatus​

Indicates the current playback state of a ringtone or music. A value of 0 typically indicates stopped or idle, and 1 indicates playing. It allows querying and controlling whether audio is currently playing.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueRingtonePlayStatusEnum80✔✔✔
Supported Valueslist[RingtonePlayStatusEnum8]✔✘✘
Default Valueuint80✔✔✘

RingtonePlayDuration​

Indicates the playback duration of a ringtone or music. The value represents the playback time in seconds. A value of 0 means play once; a value greater than 0 means play for the specified number of seconds.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint320✔✔✔
Maxuint324.294967295E9✔✘✘
Minuint320.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint320✔✔✘

BridgedNodeList​

Represents the list of bridged-node Device IDs added to this Bridge Node. It is an array of strings.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

SupportedHubCapability​

This attribute reports, as a bitmask, the core capabilities of the gateway as a smart-home hub. Each bit represents a specific capability, such as local automation, data storage, or AI support. Higher-level applications use it to discover and adapt to advanced device features for differentiated experiences.

bit 0: Supports basic gateway functions, including creating gateway clusters.

bit 1: Includes the local automation module ha_driven.

bit 2: Supports gateway local data storage (NAS).

bit 3: Supports SaaS.

bit 4: Supports local AI.

bit 5: Supports LAN app control.

bit 6: Supports running Aqara Studio.

bit 7: Supports Aqara Studio logic blocks.

bits 8–31: Reserved.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint32✔✘✔
Maxuint324.294967295E9✔✘✘
Minuint320.0✔✘✘
Stepuint321.0✔✘✘

MatterBridgeSupported​

Indicates whether the current gateway version supports Matter Bridge. If true, the app can show the “Start Matter Journey” entry and the “Bind Matter” option in device details; if false, these entries are hidden. Values: false = unsupported; true = supported.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✘✔

MatterDACState​

Indicates the readiness state of the Matter Device Attestation Certificate (DAC). 0: retrieving the DAC; 1: DAC retrieval failed; 2: DAC ready.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueMatterDACStateEnum8✔✘✔
Supported Valueslist[MatterDACStateEnum8]✔✘✘

MatterOnboardingPayload​

Provides the commissioning information required for Matter. The value is a JSON object containing an onboarding-payload string and a manual pairing code. Example: {"onboarding_payload":"MT:AR7A0OEP01C26Y2SQ10","manual_pairing_code":"0118-064-9202"}.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

MatterManufacturerList​

Provides a list of Matter ecosystems (fabrics) to which the device is bound. The value is a JSON array; each object contains vendor_id (a decimal integer), Manufacturer (a display-name string), fabric (a shared trust-domain identifier), and node_id (a device-identifier string). Example format: {"list":[{"vendor_id":24582,"Manufacturer":"Google","fabric":"10001","node_id":"10001"}, ...]}.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

MatterBindState​

Indicates the device's Matter binding state. 0: not bound to any Matter ecosystem; 1: successfully bound to at least one Matter ecosystem.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueMatterBindStateEnum8✔✘✔
Supported Valueslist[MatterBindStateEnum8]✔✘✘

MatterPairingState​

Indicates the current Matter pairing state or error reason. Possible values: 0x00 = not in pairing mode; 0x01 = standard pairing mode active; 0x02 = device binding limit exceeded (maximum 10), remove some ecosystems and try again; 0x03 = device certificate invalid, try again later; 0x04 = preparing, try again later.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueMatterPairingStateEnum8✔✘✔
Supported Valueslist[MatterPairingStateEnum8]✔✘✘

MatterPairingSwitch​

Writing true starts Matter pairing mode on the bridge; if not completed, pairing mode exits automatically after 10 minutes. Writing false immediately disables pairing. Reading indicates whether pairing mode is currently active. Values: true = enter pairing; false = turn off/disable pairing.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✔✔

TargetGarageDoorState​

This Trait is used to access and report target garage-door-state data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueTargetGarageDoorStateEnum8✔✔✔
Supported Valueslist[TargetGarageDoorStateEnum8]✔✘✘

CurrentGarageDoorState​

Describes the current garage-door state. Values: 1 = Unknown, 2 = Open, 3 = Closed, 4 = Opening, 5 = Closing, 6 = Not Fully Open, 7 = Not Fully Closed.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueCurrentGarageDoorStateEnum8✔✘✔
Supported Valueslist[CurrentGarageDoorStateEnum8]✔✘✘

SleepQuality​

Defines sleep quality, with a range of 0 to 100.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valuefloat0✔✘✔
Maxfloat100.0✔✘✘
Minfloat0.0✔✘✘
Stepuint321.0✔✘✘
Default Valuefloat0✔✔✘

SleepStage​

Defines the sleep stage.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueSleepStageEnum8✔✘✔
Supported Valueslist[SleepStageEnum8]✔✘✘

SleepState​

This Trait is used to access and report sleep-state data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueSleepStateEnum8✔✘✔
Supported Valueslist[SleepStateEnum8]✔✘✘

OnBed​

Defines the in-bed state.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✘✔

BinaryInputPV​

BinaryInputPV reports the instantaneous logical state of a discrete input and can optionally describe polarity inversion.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean0✔✘✔
Default Valueboolean0✔✔✘

LeakState​

This Trait is used to access and report leak-state data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✘✔

VehicleDetected​

Enables the device to identify vehicles in the monitored area. When a vehicle is observed entering, moving, or parking, a vehicle-detection event is reported automatically.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueVehicleDetectedEnum8✘✘✔
Supported Valueslist[VehicleDetectedEnum8]✔✘✘

BSSID​

BSSID indicates the BSSID of the Wi-Fi network to which the node is currently connected.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValuecharacterString✔✘✔

IRBrand​

Indicates the brand identifier of an infrared device, such as an air conditioner or television.

The corresponding Trait code in the specification source is IRBrandId.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint320✔✔✔
Maxuint324.294967295E9✔✘✘
Minuint320.0✔✘✘
Stepuint321.0✔✘✘
Default Valueuint320✔✔✘

MinPINCodeLength​

This Trait is used to access and report minimum PIN-code-length data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint8✔✘✔
Maxuint8255.0✔✘✘
Minuint80.0✔✘✘
Stepuint321.0✔✘✘

MinRFIDCodeLength​

This Trait is used to access and report minimum RFID-code-length data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint8✔✘✔
Maxuint8255.0✔✘✘
Minuint80.0✔✘✘
Stepuint321.0✔✘✘

OperatingMode​

This Trait is used to access and report operating-mode data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present ValueOperatingModeEnum8✔✘✔
Supported Valueslist[OperatingModeEnum8]✔✘✘

ActuatorEnabled​

This Trait is used to access and report actuator-enable data.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueboolean✔✘✔

ExtendedPANID​

Present Value is a 64-bit unique identifier used to identify a personal area network (PAN) in a Thread network. It is used with PANID to distinguish different networks. Each network has a unique ExtendedPANID, and all nodes joining that network must use the same ExtendedPANID to communicate with one another.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueuint64✔✘✔
Maxuint641.8446744073709552E19✔✘✘
Minuint640.0✔✘✘
Stepuint321.0✔✘✘

ModeCount​

Describes the number of modes supported by the device. Format: int.

Parameters​

NameTypeDefaultReadableWritableReportable
Present Valueint32✔✘✔
Maxint324.294967295E9✔✘✘
Minint320.0✔✘✘
Stepuint321.0✔✘✘